14. REINSTALL HI-FLOW BAFFLE FILTERS
Remove protective plastic film covering hybrid baffle filters before installing them.
Remove tapes (2) holding the grease rail in place.
B Insert the end of the hybrid baffle filter in the front channel of
the hood.
C Raise the other end toward the inside and insert it in the back
channel of the hood.
15. CRT OPTION ACTIVATION INSTRUCTIONS FOR WPP1366SS ONLY
Risk of electrical shock. This procedure must be done by qualified personnel in accordance with all applicable
codes and standards. Before proceeding, switch power off at service panel and lock service disconnecting means
to prevent power from being switched on accidentally.
IMPORTANT NOTE: The CRT (Code Ready Technology™) option allows changing the blower output from the factory setting (600 CFM) to
a maximum of 400 CFM or 300 CFM. The CRT option activation will reduce the hood airflow thus performing within the minimal allowable
limit of Make-Up Air (MUA) codes to meet some building code requirements. Do not attempt to change the factory blower CFM setting
unless this change is required. This change will alter the performance of your product.
How to activate the CRT option:
1.
Locate the dip switches on the electronic board.
2.
Using a precision screwdriver, set the dip
switches as per one of the illustrations
hereafter.
3.
Locate the label, next to the blower specifications label, then mark the corresponding box.
CAUTION
CAUTION
B
HD1537
! !
WARNING
VQ0010
HR0215
ON
1
2
3
4
HR0214A
12
C
ON
300 CFM
SETTING
1
2
3
400 CFM
SETTING
4