8. CONNECT WIRING (
6. Connect the power cable to the range hood wires using provided wire connectors. Connect BLACK to BLACK, WHITE to WHITE and
GREEN or bare wire under GREEN ground screw located inside the hood. DO NOT FORGET TO CONNECT THE GROUND.
7. Reinstall electrical cover removed at step 5.
Make sure not to pinch any wire when reinstalling the electrical cover.
HE0497
9. INSTALL 8" ADAPTER/DAMPER
Using 4 no. 8 x 3/8" screws from parts bag, assemble the adapter/damper on the top of the hood. To ensure proper opening of the dampers,
remove shipping tape if present. Seal all joints with metal foil duct tape to eliminate air leaks.
10. INSTALL 10" ADAPTER/DAMPER
B Using 2 no. 8 x 3/8" screws from parts bag,
assemble the adapter on the top of the hood.
Seal all joints with metal foil duct tape to
eliminate air leaks.
C Install 10" in-line damper inside the vertical
ductwork that will be attached to the hood. Do
not install in a horizontal ductwork or it will not
open and close properly. Remove shipping tape
if present. Secure the damper to the duct with 3
no. 8 sheet metal screws (not provided). Ensure
damper opens and closes freely. Seal all joints
with metal foil duct tape to eliminate air leaks.
)
continued
CAUTION
B
HD1529
HD1539
9
C
10" min.
recommended
HD1540