NOTE
1. The osmosis unit can be used directly for drinking.
2. When absent for more than 24 hours, disconnect the power supply from the
water purifier and the water source. However, there is a risk of contaminating
the membrane if the period of time is too long
MAINTENANCE
1. FILTER REPLACEMENT CYCLE
After being used for a certain period of time, various impurities will accumulate in the
filter element, which will affect the water output rate, the temperature of the unfiltered
public tap water, the water pressure and the water quality under the premise of this
manual. The replacement cycle of each filter element is as follows:
Filter type
Normal service life
NOTE
Water quality has a great influence on the service life of the filter elements and the
service life of the reverse osmosis membrane. Other filter elements are affected by
many factors.
Factors: in the process of actual use, due to different water quality, their service life
may be shorter than the above data. These data are for reference only.
Generally, the filter element should be replaced if the following conditions occur:
When the effluent quality is poor, a strange taste is perceived.
The filter element is severely blocked, resulting in the osmosis unit not being able to
produce water or the osmosed water not being able to flow out.
2. STEPS FOR REPLACING THE FILTER
To guarantee the good filtering effect of each filter element and to ensure that the
water reaches the drinking water level, users must replace or clean the filter element.
The replacement of the filter element must be carried out by professional water
installation and maintenance personnel.
PCT front and rear
composite filters
12 months
31
Reverse osmosis
membrane filter
24 months