Descargar Imprimir esta página

Piusi SUZZARABLUE AC Instalación Uso Y Mantenimiento página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

EN (Translation of the original language)
13
CONNECTIONS
13.1
ELECTRICAL CONNECTIONS
ATTENTION
WARNING
- During installation and maintenance make sure that power supply to the electric lines has been
turned off.
- Use cables with minimum sections, rated voltages and installation type that are suitable for
the characteristics indicated in paragraph "ELECTRICAL DATA" and the installation environment.
- Always make sure that the cover of the terminal strip box is closed before switching on the pow-
er supply, after having checked the integrity of the seal gaskets that ensure the IP55 protection
grade.
- All motors are equipped with a grounding terminal that is to be connected to the ground line
of the electrical system.
PUMP FIT-
The pump is fitted with:
- single-phase motor with 2-mt. power cord
TINGS
- bipolar switch
- capacitor
Wired and installed inside the terminal strip box (see chart)
NOTE
SWITCH
SWITCH
This manual belongs to PIUSI S.p.A. Whole or partial reproduction of this manual is forbidden.
IT IS THE INSTALLER'S RESPONSIBILITY TO CARRY OUT THE ELEC-
TRICAL CONNECTIONS IN COMPLIANCE WITH THE RELEVANT
STANDARDS.
Comply with the following (not exhaustive) instructions to ensure a proper
electrical connection:
The capacitor characteristics are those indicated on the pump label. The switch has
the only function of starting/stopping the pump and cannot in any way replace the
main power switch required by the relevant standards.
BLACK
BLACK
RED
RED
CAPACITOR
WHITE
WHITE
DIAPHRAGM PUMP AC
RED
RED
CONDENSADOR
11
11 /48
/124

Publicidad

loading

Este manual también es adecuado para:

F00203010F0020310h