• Servicing shall be performed
only as recommended by the
manufacturer.
WARNING: THE
APPLIANCE SHALL
BE STORED IN A
WELL-VENTILATED
AREA WHERE THE
ROOM SIZE
CORRESPONDS TO
THE ROOM AREA
AS SPECIFIED FOR
OPERATION.
WARNING: THE
APPLIANCE SHALL
BE STORED IN A
ROOM WITHOUT
CONTINUOUSLY
OPERATING OPEN
FLAMES (FOR
EXAMPLE AN
OPERATING GAS
APPLIANCE) AND
IGNITION SOURCES
(FOR EXAMPLE AN
OPERATING
ELECTRIC HEATER).
• Under no circumstances shall
potential sources of ignition be
used in the searching for or
detection of refrigerant leaks.
A halide torch (or any other
detector using a naked flame)
shall not be used.
5059340368191_MNL_IN_V04.indd 4
5059340368191_MNL_IN_V04.indd 4
• For leak detection, the use of
detergents containing chlorine
shall be avoided.
• If a leak is suspected, all
naked flames shall be
removed/extinguished.
• Call the service agent
immediately and keep far
away from the product.
• If disposal or decommissioning
is needed, please contact the
service agent or authorized
personal to do it. Do not
dispose and decommission
the product yourself.
• The appliance shall be
installed in accordance with
national wiring regulations.
The maximum refrigerant
charge amount: 290g.
• An unventilated area where
the appliance using flammable
refrigerants is installed shall
be so constructed that should
any refrigerant leak, it will not
stagnate so as to create a fire
or explosion hazard.
• The appliance shall be stored
so as to prevent mechanical
damage from occurring.
• Check that cabling will not be
subject to wear, corrosion,
excessive pressure, vibration,
sharp edges or any other
adverse environmental effects.
The check shall also take into
account the effects of aging
4
30-11-2022 14:53:22
30-11-2022 14:53:22