After processing
6.2.
• Press the
button on the control panel to stop the current
supply to the DW wand.
• Put the DW wand back in its holder (A).
At the end of processing, always store the DW
wand and other accessories appropriately.
Never place the wand on top of the device
during breaks or at the end of processing,
as the electrolyte solution could drip from the
dampened brush/pad and penetrate inside
the unit. Always use the appropriate holder
and empty the collection tray when necessary.
The device should in any case be kept as
clean as possible.
• Disconnect the ground cable crocodile clip from the machined part.
• Wipe out excess of electrolyte solution with a microfiber cloth
• Use the SURFOX-N solution on the treated piece.
It is very important to spray the SURFOX-N
solution on the workpiece; this product
neutralizes any residual electrolyte, thus
avoiding the formation of halos and white
spots (which can only be eliminated by
repeating the entire process).
Alternatively, it is possible to clean the surface
with an abundant jet of water.
• Rub the surface with a microfiber cloth
• Dry the surface using a dry microfiber cloth.
Shutdown
6.3.
• Turn off the device by turning the main switch to the "O" position.
• Disconnect the unit plug from the power supply socket.
• Carry out routine maintenance on the device as described in chapter 8.1.
• To limit any environmental impact, used pad and used liquids must always be disposed of in accordance with current waste
disposal regulations (see chapter 9 for additional information).