Professional True RMS Digital Multimeter with OLED display / English
31. Specifications
Accuracy calculated as [%reading + (num. digits*resolution)] at 18°C ÷ 28°C <75%HR.
DC Voltage
Range
Resolution
Accuracy
60.00mV
0.01mV
600.0mV
0.1mV
±(0.5%reading
+ 5digits)
6.000V
0.001V
60.00V
0.01V
600.0V
0.1V
±(0.8%reading
+ 5digits)
1000V
1V
AC TRMS Voltage
Range
Resolution
(50Hz - 60Hz)
60.00mV
0.01mV
600.0mV
0.1mV
6.000V
0.001V
±(1.0%reading
+ 5digits)
60.00V
0.01V
600.0V
0.1V
1000V
1V
(*)Accuracy specified from 5% to 100% of the measuring range,
Input impedance: >9MΩ;
60/600.0mV RANG (50----400Hz)
Distorted, pulsed, triangle or trapezia waveform Accuracy: ±(10%rdg + 10dgt).
Accuracy PEAK function: ±10%rdg, PEAK response time: 1ms
18
Input
Protection against
impedance
overcharge
>10MΩ
1000VDC/AC RMS
Accuracy (*)
Protection against
overcharge
(61Hz-1kHz)
±(3.0%reading
1000VDC/AC RMS
+ 5digits)
Professional True RMS Digital Multimeter with OLED display / English
AC+DC TRMS Voltage
Accuracy
Range
Resolution
(50Hz÷1kHz)
6.000V
0.001V
60.00V
0.01V
±(3.0%reading
+ 40dgt)
600.0V
0.1V
1000V
1V
(*)Accuracy specified from 10% to 100% of the measuring range,
Input impedance: >9MΩ;
DC Current
Range
Resolution
600.0µA
0.1µA
6000µA
1µA
±(1.0%reading + 5digits)
60.00mA
0.01mA
600.0mA
0.1mA
±(1.0%reading + 8digits)
6.000A
0.001A
±(1.5%reading + 8digits)
10.00A
0.01A
AC TRMS Current
Range
Resolution
600.0µA
0.1µA
6000µA
1µA
±(1.2%reading + 5digits)
60.00mA
0.01mA
600.0mA
0.1mA
6.000A
0.001A
±(1.5%reading + 8digits)
10.00A
0.01A
(*)Accuracy specified from 5% to 100% of the measuring range.
Distorted, pulsed, triangle or trapezia waveform Accuracy: ±(10%rdg + 10dgt)
Input
Protection against
impedance
overcharge
>9MΩ
1000VDC/AC RMS
Protection against
Accuracy (*)
overcharge
Quick fuse
800mA/1000V
Quick fuse 10A/1000V
Accuracy (*)
Protection against
(50Hz÷1kHz)
overcharge
Quick fuse
800mA/1000V
Quick fuse 10A/1000V
19