Descargar Imprimir esta página

Frigidaire CPDS3085PFE Instrucciones De Instalación página 7

Cocinas de dual fuel de 30"

Publicidad

Idiomas disponibles

Idiomas disponibles

m
Electrical
Connection
to the
Range
(U.S.A.)
Three
Conductor
Wire Connection
to
Range
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power
supply cord (see Figure 3):
1. Remove the screw which is fixing the rear wire
cover, then remove the rear wire cover (access
cover) to expose range terminal connection
block
(see Figure 2).
2. Using the nuts supplied in the literature package,
connect the neutral of the copper power supply
cord to the center silver-colored
terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal) (see figure 3).
3. Put back the rear wire cover using the screw
removed on step 1.
Grounding
Silver Colored Terminal
Four Conductor
Wire Connection
to Range
Where local codes does NOT permit connection
of the
frame grounding conductor to the neutral wire of the
copper power supply cord (see Figure 4):
1. Remove the screw which is fixing the rear wire
cover, then remove the rear wire cover (access
cover) to expose range terminal connection
block
(see Figure 2).
2. Remove the grounding strap from the terminal
block and from the appliance frame.
3. Using the nuts supplied with the literature package,
connect the ground wire (green) of the copper
power supply cord to the frame of the appliance with
the ground screw, using the hole in the frame where
the ground strap was removed (see Figure 4).
4. Connect the neutral of the copper power supply
cord to the center silver-colored
terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal).
5. Put back the rear wire cover using the screw
removed on step 1.
Terminal Block
Red Wire
Silver Colored Terminal
Red
W ire
Terminal
Block
Black
Wire
A User Supplied
Strain-relief Must
Be Installed at This
Location.
To 240 V
Receptacle
Figure 3
1 1/8" (2,9 cm) Dia.
Direct Connection
Hole. Punch Out
Knockout for 1 3/8"
(3,5 cm) Dia. Cord
Kit Hole.
Black Wire
!
1 1/8" (2,9cm) |
Dia. Direct
I
Connection
Hole. Punch
Out Knockout
for 1 3/8" (3,5
cm) Dia. Cord
Kit Hole.
A User Supplied
Strain-relief Must
Be Installed at
This Location
To 240 V Receptacle
NOTE: Be sure to remove the
supplied grounding strap.
Figure 4
7

Publicidad

loading

Este manual también es adecuado para:

Fgds3065pfrFgds3065pfgFgds3065pfpCgds3065pfnFgds3065pfm