Installation
4
4.9
Calibration of the thermal relay
The thermal relay serves to avoid damage to the motor due to an
excessive absorption increase or if a phase is missing.
Refer to the table in wiring diagram No. 5 of Appendix A for the
calibration.
2
To reset, in case of an intervention of the thermal relay, press button 1)
of Fig. 21.
Voltage 3 ~ 415 / 240V - 50/60 Hz
The RS 130/M models leave the factory pre-set for 415 V power sup-
ply.
1
Fig. 21
D8267
20032905
17
GB