30
Section 02
GAS FLOW
SYMPTOMS
01. A flame is coming out of the air gate.
POSSIBLE CAUSES
01. Something is blocking the venturi
in the burner tube. This is not
allowing the propane to flow
through the burner, causing the
flame to back out the air gate.
SYMPTOMS
01. Burner flames are yellow or irregular.
POSSIBLE CAUSES
01. Something is blocking the
air gate for the burner. This is
blocking oxygen from mixing
with the propane correctly to get
healthy flames.
SOLUTION
Clean the burner assembly to remove
the obstruction. (Please reference the
Cleaning the Burner Assembly section
of the Care & Maintenance chapter.)
SOLUTION
Check the air gates in your burner. If
you have adjustable air shutters over
your air gates, make sure that they are
completely open. If your burners have
bug shields, clean any spider webs, soot,
or debris off the bug shield. Clean any
other obstructions out of air gates.
Model 1845