DANGER
Risk of Electric Shock, frame grounded to neutral of appliance
through a link.
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or in an area where local codes prohibit
grounding through the neutral conductor.
3 - Wire branch circuit
Where local codes allow the connection of ground wire from
the cooktop to the branch circuit neutral wire (gray or white
colored wire) proceed as follows (see figure 13).
1. If local codes permit, connect the green GROUND wire
from the cooktop to the branch circuit neutral wire (gray or
white colored wire).
2. Connect the red and black leads from the cooktop to the
corresponding leads in the junction box.
FIGURE 13
4-Wire branch circuit
Refer to figure 14:
1. Connect the green ground wire from the cooktop to the
ground wire in the junction box (bare or green colored
wire).
2. Connect the red and black leads from the cooktop to the
corresponding leads in the junction box.
3. Terminate and insulate the neutral (gray or white colored
wire) in the junction box.
FIGURE 14