10. Decommissioning
10.1
Changing location
If the CRI/CRIN SST is handed over to someone
c
else, hand over all the documentation included in
the scope of delivery as well.
Only transport the CRI/CRIN SST in its original or
c
equivalent packaging.
10.2
Disposal and scrapping
10.2.1 Substances hazardous to water
Oils and greases as well as refuse containing oil and
!
grease (e.g. filters) represent a hazard to water.
1. Substances hazardous to water must not be al-
lowed to enter the sewage system.
2. Substances hazardous to water must be disposed
of in accordance with the applicable regulations.
Test oil conforming to ISO 4113 is classified under
!
waste oil collection category 1. Collection catego-
ry 1 waste oil must not contain any foreign sub-
stances, e.g. waste oils belonging to another cate-
gory, or gasoline or diesel. See the test oil safety
data sheet for the correct waste code number.
10.2.2 CRI/CRIN SST and accessories
Dismantle the CRI/CRIN SST, sort the components
c
by materials, and dispose of them in accordance
with applicable regulations.
Robert Bosch GmbH
Decommissioning | CRI/CRIN SST | 7 |
11. Replacement and wearing
parts
Designation
Pressure sensor
Adapter for pressure sensor<)
Sealing cone<)
Wearing part
<)
12. Technical data
Designation
Test pressure max.
Pressure sensor maximum pressure
Pressure sensor voltage supply
Injections per minute
Total actuation time of the actuation profile
en
Order number
1 687 231 266
1 685 720 435
1 683 387 114
Value
250 MPa
350 MPa
12 VDC
100 – 2000
150 µs – 3000 µs
|
1 689 989 563
2023-08-01