Make sure the electric and/or gas installation is proper. If not, call a qualified electrician and
installer for the required operations.
Electric and/or gas installation of the place where the product will be used should be done by
the customer.
Observe the local standards related to electric and/gas during installation of the product.
Control the product prior to use for any damage on it. If the product has any damage, do
not allow installation. Damaged products would cause risk for your safety.
Any operations on the gas equipment and systems should be performed by qualified and
authorized persons.
The product has no system to discharge the gases that form as a result of combustion. The
product should be installed and connected as per the applicable installation regulations.
Show attention to the requirements concerning ventilation.
Air necessary for combustion is taken out of the room air and the resulting gases are
directly given into the room.
It is essential that the room should be ventilated well for safe operation of the product. If
there is no window or door that may be used for ventilation of the room, extra ventilation
should be installed.
Footprint o the kitchen should be bigger than 8m
Kitchen volume should be bigger than 20m
Kitchen outlet should be in height of 1.80m from the floor and should have an opening in
diameter of 150mm to the atmosphere.
Ventilation grill should be minimum 75cm
atmosphere.
2
.
3
.
2
, near the kitchen floor, opening to the outer
9
V.1