LPG connection
Show great care that the gas hose and gas relief valve you will use on your furnace are safe. Fix the
gas supply hose on the hose nozzle on the rear of the furnace and tighten it by a sheet clamp and
screwdriver (Figure 6). Make sure it is tightened well.
Length of the furnace gas hose should not be longer than 1500m. Pressure of the relief valve to be
used for LPG should be 300mmSS and certificated.
Gas supply hose should not run through the hot part at the rear of the furnace. Gas hose
should not exceed 90
Prior to use, make sure the system is leakage proof.
NG (natural gas) connection
Figure 7
If your equipment has natural gas setting, have it connected by the concerning natural gas
supply company. Natural gas connection of your product is ½”. When you desire to convert
your equipment from LPG to natural gas or from natural gas to LPG, apply to the nearest
service center and have the gas conversion settings done.
Leakage control
Open the relief valve or natural gas valve and control with highly foamed soap water for any
gas leakage on the connection you have made.
Never control it with flame.