Descargar Imprimir esta página

Lincoln Electric LMA 75 1.0 m Manual De Instalación Y De Uso página 7

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
4.5
Mounting
PA | Stanchion
To install the LMA 75 on a stanchion, refer to the
instruction sheet that is supplied with the PA. Refer
to the available product data sheet for mounting
examples.
The package contains no mounting hardware for the mounting
bracket, since the required mounting hardware depends on the
wall type.
WARNING!
Before you install the product, make sure that the
wall or mounting structure is strong enough. Refer
to § 1.5 for the weight of the product.
4.5.1
Mounting bracket
Fig. 4.2
Determine the desired installation height.
Install the mounting bracket (including the arm) to the wall
or mounting structure.
A
A
162 mm
B
202 mm
C
186 mm
D
30 mm
E
79 mm
MiniMan-75
Fig. 4.2 Mounting bracket
5
USE
Personal protective equipment (PPE)
During use, use PPE to avoid injury. This
also applies for persons who enter the work
area.
Fig. 5.1
Take the nozzle (A) to position it at max. 225 mm above
the source of pollution.
Make sure that the DAMPER-75 (shut-off valve), if any, is
open.
0000117805/01MAY2023/0 LMA 75 1.0 m | LMA 75 1.5 m
A
B
C
D
D
E
Turn on the connected extraction fan or system.
Start working.
If desired, partly close the valve to adjust the airflow.
When the working position changes, move the nozzle to
the correct position in relation to the workpiece.
Turn off the connected extraction fan or system approx. 20
seconds after finishing the work.
B
A
A
A = max. 225 mm
B = >225 mm
Fig. 5.1 A = Correct position of the nozzle (example: soldering)
6
MAINTENANCE
6.1
Periodic maintenance
The product has been designed to function without
problems for a long time with a minimum of
maintenance. In order to guarantee this some simple, regular
maintenance and cleaning activities are required which are
described in this chapter. If you observe the necessary caution
and carry out the maintenance at regular intervals, any
problems occurring will be detected and corrected before they
lead to a total breakdown.
WARNING!
Overdue maintenance can cause fire.
The indicated maintenance intervals can vary depending on
the specific working and ambient conditions. Therefore we
recommend to thoroughly inspect the complete product once
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
A
Component
Action
Outside of
Clean with a non-aggressive
the arm
detergent
Flexible hoses
Check for cracks or damages. Replace
if necessary
Inside of the
Clean thoroughly
arm
Arm
Check the movement of the arm. If
MiniMan-100
movement
necessary, adjust the friction; refer to
§ 6.2
6.2
Arm adjustment
If the extraction arm, or a part of it, does not stay in the
desired position, you must adjust the friction.
Fig. 6.1
Determine which part of the arm needs more or less
friction;
- inner tube (ref. Fig. 2.1E): adjust friction joint A
- outer tube (ref. Fig. 2.1F): adjust friction joint B
B
B
C
C = >0 mm
B
C
Frequency:
every X
months
X=3
X=6
X
X
X
X
EN | 5
C
D
D
E

Publicidad

loading

Este manual también es adecuado para:

Lma 75 1.5 m