4.3.6 Travel Learning
Attention: The control board must learn the travel limit before it can be used normally.
Before the travel learning operation, you must be ensured that the limit is not triggered.
Then press and hold the button WORK. The motor will run closing first and led CLOSING flashes. After the gate triggers the
closing limit, the motor will run opening and led OPENING flashes. When the gate triggers the opening limit, the motor will
run closing again. Finally, as the gate triggers closing limit, travel learning is completed.
4.3.7 Extra button
PAUSE:
This button is used to set the automatic closing time .When the motor is not running, press the button and then led
STS flashes. You can press the button again to stop flashing. The automatic closing time (seconds) depends on how many
times the led STS flashes.
START:
This button is equal to J4 TERMINAL's START port
4.3.8 Adjusting knob
TORQUE:
For motor output force adjustment to ensure safety. Clockwise rotation to increase; Counter-clockwise rotation to
reduce.
TIME:
For slow stop width adjustment. Clockwise rotation to increase; Counter-clockwise rotation to reduce.
Rotate to the minimum to cancel the slow stop function.
Note:
The default setting is TORQUE, TIME are the maximum value, and the user can adjust according to the actual require-
ment.
Warning: The motor output force cannot set too large, just to be able to drive the gate.
4.3.9 Dip switch
1. AUTO CLOSING:OFF-- No automatic close function; ON--Automatic close function.
2. RX 4 BUTTON: OFF—Single button mode remote control; ON—Three button mode remote control.
3. SBS MODE: OFF—Pedestrian mode; ON—No pedestrian mode.
4. MOT.DIRECTION: OFF—Left installation; ON---Right installation.
4.3.10 Infrared connection
Note: The infrared connection NC or NO will be memorized while Travel Learning.