Maintenance
Check the connections between the battery and the machine and also
check the connection between battery and the battery charger.
To do a check of the air intake
1. Make sure that the air intake is not blocked.
(Fig. 32)
2. Stop the product and remove leaves or
unwanted material if it is necessary.
CAUTION:
decreases the blowing capacity of
the product and increases the work
temperature of the motor. If the
motor becomes too hot, it can result
in motor failure.
To examine the battery and the battery
charger
1. Examine the battery for damages, for example
cracks.
Keypad
Keypad
Green LED flashing
Battery
Condition
The battery warning LED
flashes.
The battery warning LED
comes on.
1516 - 008 - 29.11.2023
A blocked air intake
Troubleshooting
Possible faults
Low battery power.
Possible faults
Temperature deviation,
the battery is too cold or
too hot to use.
The battery is empty.
Permanent battery error.
2. Examine the battery charger for damages, for
example cracks.
3. Make sure that the connection cord of the
battery charger is not damaged and that there
are no cracks in it.
To clean the product, the battery and
the battery charger
1. Clean the product with a dry cloth after use.
2. Clean the battery and battery charger with a
dry cloth. Keep the battery guide tracks clean.
3. Make sure that the terminals on the battery
and the battery charger are clean before the
battery is put in the battery charger or the
product.
Possible action
Charge the battery.
Possible procedure
Let the battery cool down or move it indoors to
warm it up. When the battery has the correct
temperature, it can be used again. Use the
battery in ambient temperatures between 14°F
(-10°C) and 104°F (40°C).
Charge the battery.
Speak to your dealer.
Daily
Weekly
Monthly
X
17