Descargar Imprimir esta página

SICK GTE6V Instrucciones De Uso página 25

Ocultar thumbs Ver también para GTE6V:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
7.1
Troubleshooting table
8
Disassembly and disposal
9
Maintenance
8021850.1HTG/2022-11-11 | SICK
Subject to change without notice
Table 4: Troubleshooting
LED/fault pattern
Green LED does not light up
Green LED does not light up
Green LED does not light up
Yellow LED flashes
Yellow LED lights up, no object
in the path of the beam
Object is in the path of the
beam, yellow LED does not
light up
Object is in the path of the
beam, yellow LED does not
light up
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
This SICK sensor is maintenance-free.
OPERATING INSTRUCTIONS
Cause
No voltage or voltage below
the limit values
Voltage interruptions
Sensor is faulty
Sensor is still ready for oper‐
ation, but the operating condi‐
tions are not ideal
Excessive background remis‐
sion
Sensitivity is set too low or dis‐
tance between the sensor and
the object is too long
Remission capability of the
object is insufficient
O P E R A T I N G I N S T R U C T I O N S | GTE6V
Measures
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Ensure there is a stable power
supply without interruptions
If the power supply is OK,
replace the sensor
Check the operating condi‐
tions: Fully align the beam
of light (light spot) with the
object / Clean the optical sur‐
faces / Readjust the sensitiv‐
ity (potentiometer)
Check changes to the back‐
ground. Reduce the sensitivity
of the sensor or use sensors
with background suppression
Increase the sensing range,
take note of the distance
between the sensor and the
background
Increase the sensing range,
take note of the distance
between the sensor and the
background
25
en

Publicidad

loading