Technical specifications
Sensing range
Sensing range max.
Light spot size / distance
Supply voltage U
B
Output current I
max.
Switching frequency
Response time
Enclosure rating
Protection class
Circuit protection
Ambient temperature, operation
1)
Object with 90% remission factor (complies with standard white according to DIN 5033)
2)
Limit values
Reverse polarity protected U
B
Residual ripple max. 5 V
ss
3)
With light / dark ratio 1:1
4)
Signal transit time with resistive load
5)
IP68: according to EN 60529 (water depth of 1 m / 24 h).
IP69K: according to ISO 20653:2013-03.
6)
Reference voltage DC 50 V
7)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
11
Annex
11.1
Conformities and certificates
8021850.1HTG/2022-11-11 | SICK
Subject to change without notice
connections
You can obtain declarations of conformity, certificates, and the current operating
instructions for the product at www.sick.com. To do so, enter the product part number
in the search field (part number: see the entry in the "P/N" or "Ident. no." field on the
type label).
OPERATING INSTRUCTIONS
GTE6-xxx1xV
GTE6-xxx2xV
12 ... 250 mm
45 ... 700 mm
10 ... 300 mm
30 ... 900 mm
1)
6 mm / 100 mm
8 mm / 100 mm
DC 10 ... 30 V
2)
DC 10 ... 30 V
100 mA
100 mA
500 Hz
3)
500 Hz
3)
< 1.25 ms
< 1.25 ms
4)
IP67, IP68,
IP67, IP68, IP69K
IP69K
5)
III
III
6)
6)
A, B, D
A, B, D
7)
7)
-25 °C ... +55 °C
-25 °C ... +55 °C
O P E R A T I N G I N S T R U C T I O N S | GTE6V
GTE6-xxx3xV
40 ... 760 mm
30 ... 900 mm
1)
1)
6 mm / 100 mm
2)
DC 10 ... 30 V
2)
100 mA
500 Hz
3)
< 1.25 ms
4)
4)
IP67, IP68, IP69K
5)
5)
III
6)
A, B, D
7)
-25 °C ... +55 °C