Descargar Imprimir esta página

American Standard Fluent 7186.201 Instrucciones De Instalación página 4

Grifo para lavabo de centro con desagüe speed connect
Ocultar thumbs Ver también para Fluent 7186.201:

Publicidad

Idiomas disponibles

Idiomas disponibles

10
TEST INSTALLED FITTING
• With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
• Remove AERATOR (3).
• Operate HANDLE (1) to flush water lines thoroughly.
• Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
• Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in Sink. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
• Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks.
if necessary.
11
SERVICE
CAUTION
• To remove or replace cartridge:
– Turn valves to OFF position.
– Turn off water supplies.
– Loosen SET SCREW (1) with 5/64" HEX WRENCH (2).
– Pull HANDLE (3) "UP" firmly to release from
PLASTIC INSERT (4, 5 or 6).
– Remove SCREW (7) and pull off
PLASTIC INSERT (4, 5 or 6).
– Remove RETAINING O-RING (8).
– Lift and turn STOP WASHER (9) 90˚.
– Replace RETAINING O-RING (8).
– Re-install HANDLE ASSEMBLY
• AERATOR (10) may accumulate dirt causing
distorted and reduced water flow. Remove
AERATOR (10) and rinse to clear any debris.
• If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
12
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
Tighten
Turn off hot and cold water
supplies before beginning.
4
1
2
2
1
7
4
RED
5
9
BLUE
90˚
90˚
WASTE
OUTLET
"P" TRAP
3
6
8
9
M965624 Rev. 1.4 (3/22)