INCLUDED PARTS
Controller & Tank
TLK01101UA, TLK01101UiA
TLK01103UA, TLK01103UiA
TLK01107UA, TLK01107UiA
Note:Outer cover of TLK0110xUiA has opening on its right side.
Sub-Tank Unit (TLK01401U)
Hose Unit (TLK01403U)
Soap Intake
Sub-Tank
Connecting hose 16' 4-7/8" (5 m)
Y-shaped nipple
Hose clamps (6)
(Continued)
TLK01102UA, TLK01102UiA
TLK01106UA, TLK01106UiA
Opening
Special Order
Connecting hose
16' 4-7/8" (5 m)
I-shaped nipple
IoT Communication Card
Hose clamps (1)
QR Code Sticker
6
INSTALLATION PROCEDURE - Positioning
Positioning the Dispenser
1. Make sure to leave at least 4-3/4" (120 mm)
of space between the soap dispenser and
the faucet to prevent accidental activation.
2. Leave 3-1/8" (80 mm) of space maximum
from the inside edge of the sink to the spout
installation hole to ensure that any residual
soap drips from the dispenser spout into the
sink bowl.
Positioning the Tank
Less than 59'' (1500 mm)
Less than 31-1/2''
Controller
(800 mm)
Tank
Install the tank within 31-1/2" (800 mm) the upper face of the counter. It also should not exceed
the height of the upper end of the controller.
It cannot be installed on the counter or on the lower level.
If it is installed beyond this range, the following troubles may occur. Less water spouts and the
soap does not foam.
The length of the hose connected to the spout is 6' (1.8 m). Install the controller so that the hose
can be connected to the controller.
(1) Space between the dispenser
and the faucet to be
4-3/4" (120 mm) minimum
Hole for installing
the dispenser
[1" – 1-1/8" (25–28 mm)
in diameter]
Faucet
(2) The distance from the
soap dispenser to the
edge of the sink to be
3-1/8" (80 mm) maximum
Touchless Soap Dispenser
Sink
(Unit: Inch (mm))
Less than 55'' (1400 mm)
(Height of controller:
14'' (350 mm))
Spouts