TROUBLESHOOTING
n
Before performing any maintenance and clearing work operation , please take the spark-plug cap off.!
FAULT
The engine does not start
The engine power goes down
The tines are not rotating
In case you are not able to remedy the defect/damage according to a.m. table, please contact an authorized service center only .
15
FAULT CLEARANCE
Check the fuel level, if necessary refuel.
Check the throttle to be on START position.
Check the spark-plug connector to be properly attacched.
Check the spark-plug condition and if necessary replace it.
Check the fuel valve to be in the opened position( only for the models showing
such feature).
The air filter is dirty – please clean it.
Check if any stone or soil/vegetation residue is stopping the tines rotation, in case
clean them.
Adjust the transmission cables registers.
Check the tines to be fasten to the shaft.