General Instructions
Read these instructions carefully prior to
installation and use. Keep this manual for
future reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid should the product be used
in the manner intended and in accordance with
the instructions.
Application
Panther T is a range of efficient fan heaters
designed for drying and heating installations of
a more technical nature. Panther T is suitable
in, for example, service areas, utility rooms and
drying rooms.
Protection class: IP44.
Mounting
The Panther fan heater is mounted on the
wall with the supplied bracket. The bracket
allows the fan heater to be angled downwards
and to the side (30° left or right). The product
must be mounted in such a way as to allow
future service and maintenance. For minimum
distance, see diagrams on the introduction
pages.
The bracket is fixed to the unit during
transportation to not damage the unit.
1. Detach the bracket from the unit by removing
the lower screws.
2. Mark and drill the holes for the bracket's
keyhole slots on the wall.
3. Mount the bracket on the wall in the desired
position (straight, to the left or to the right).
Use screws and plugs suitable for the wall.
4. Loosen the upper screws of the unit
approximately 10 mm and hang the unit on
the bracket.
5. Adjust the fan heater to the desired angle
and fasten it with the lower screws on both
sides of the unit.
6. Tighten all screws.
See pictures in the introduction pages.
Electrical installation
The Panther fan heater is intended for
permanent installation. The installation, which
should be preceded by an isolator switch with
a contact separation of at least 3 mm, should
16
Get In Touch
Call: 0845 6880112
Email: info@adremit.co.uk
Panther T
Installation and operating instructions
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
The power supply to the unit must
be disconnected during all service,
repair and maintenance work.
only be wired by a competent electrician and in
accordance with the latest edition of IEE wiring
regulations.
The electrical connection is made on the
back of the unit. Pierce the grommet with a
screwdriver before entering the cable. Open
the lid by removing its four screws to access
the connection area. The wiring diagram can
be found on the inside of the lid. Power supply
should be connected to the assigned terminal
block. At delivery PNT15 is connected for
400V3N~, it can be connected to either 400V3N~
or 230V3~ by repositioning the Y/D (Y/∆)
connection plates. PNT135 and PNT305 can be
connected to both 440V3~ and 500V3~.
When several heaters are connected to each
other and controlled by a common accessory
it should be indicated in the distribution board
that "The fan heaters are supplied from more
than one group supply".
See wiring diagrams.
Control
Panther T must be supplemented with a control
panel PP. Up to 6 units can be controlled by
one control panel. PNT135 requires one PP15N
per unit. The output and fan speed are set on
the control panel. An external thermostat or
temperature control is highly recommended to
regulate the heat.
The thermostat can be set to activate both
fan and heat, according to selected settings, by
removing a link on the terminal block.
• PNT15/135: link between terminals 14-15
• PNT20/30/305: link between terminals 10-11
PNT15, PNT135 –
Factory setting
4
5
6
7
8
9
10
1
2
3
PNT20, PNT30, PNT305 –
Factory setting
10
1
2
3
4
5
6
7
8
9
11
12
13
14
15 16
11