Descargar Imprimir esta página

Frico Panther T Manual Del Usuario página 7

Ocultar thumbs Ver también para Panther T:

Publicidad

Panther T (IP44)
Item
Type
Output
number
steps
[kW]
334023
PNT15
0/7,5/15
334024
PNT20
0/10/20
334025
PNT30
0/10/20/30
0/5/10
334030
PNT135
0/7/13,5
0/7,5/15/23
PNT305
334034
0/10/20/30
*
) Sound power (L
1
WA
*
) Sound pressure (L
2
absorption area: 200 m². At lowest/highest airflow (when applicable).
*
) ∆t = temperature rise of passing air at maximum heat output. At lowest/highest airflow (when applicable).
3
*
) Delivered for 400V3N~, can be connected to 230V3~.
4
*
) Can be connected to both 440V3~ and 500V3~.
5
Approved for 380V/3ph/60Hz. Product performance for 380V/3ph/60Hz will differ from stated data.
EN: Output steps
FR: Puissances
DE: Abgabestufen
SE: Effektsteg
NO: Effekttrinn
DK: Effekttrin
FI: Tehoportaat
NL: Capaciteit
ES: Niveles de potencia
IT: Stadi potenza
PL: Stopnie mocy
RU: Ур. мощности
EN: Airflow
FR: Débit d'air
DE: Luftmenge
SE: Luftflöde
NO: Luftstrøm
DK: Luftmængde
FI: Ilmavirta
NL: Luchtstroom
ES: Caudal de aire
IT: Portata aria
PL: Wydajność powietrza
RU: Расх.возд.
*
) Mesures de la puissance acoustique (L
1
FR
*
) Pression acoustique (L
2
d'absorption : 200 m². Au débit d'air minimal/maximal (le cas échéant).
*
) ∆t = augmentation de température du débit d'air sous une puissance maximale. Au débit d'air minimal/
3
maximal (le cas échéant).
*
) Livré en version 400V3N~, raccordement 230V3~ possible. *
4
*
) Schallleistungsmessungen (L
1
DE
*
) Schalldruck (L
). Bedingungen: Abstand zum Gerät: 3 Meter. Richtungsfaktor: 2. Entsprechende
2
pA
Absorptionsfläche: 200 m². Bei minimalem/maximalem Volumenstrom (falls zutreffend).
*
) ∆t = Temperaturanstieg der vorbeiströmenden Luft bei max. Heizleistung. Bei minimalem/maximalem
3
Volumenstrom (falls zutreffend).
*
) Geliefert für 400V3N~, ermöglicht Anschluss an 230V3~. *
4
werden.
Get In Touch
Call: 0845 6880112
Email: info@adremit.co.uk
Airflow
Sound
power *
[m³/h]
[dB(A)]
900/1300 61
2300
71
2300
71
900/1300 61
2300
71
) measurements according to ISO 27327-2: 2014, Installation type E.
). Conditions: Distance to the unit 3 metres. Directional factor: 2. Equivalent
pA
EN: Sound power
FR: Puissance acoustique
DE: Schallleistung
SE: Ljudeffekt
NO: Lydeffekt
DK: Lydeffekt
FI: Ääniteho
NL: Geluidsvermogen
ES: Potencia acústica
IT: Potenza sonora
PL: Moc akustyczna
RU: Мощность звука
EN: Sound pressure
FR: Pression acoustique
DE: Schalldruck
SE: Ljudtryck
NO: Lydtrykk
DK: Lydtryk
FI: Äänenpaine
NL: Geluidsdruk
ES: Presión acústica
IT: Pressione sonora
PL: Ciśnienie akustyczne
RU: Звуковое давление
) selon la norme ISO 27327-2 : 2014, Installation de type E.
WA
). Conditions : Distance de l'appareil : 3 mètres. Facteur directionnel : 2. Surface
pA
) gemäß ISO 27327-2: 2014, Installationstyp E.
WA
Panther T
Sound
∆t*
Motor
3
pressure*
1
2
[dB(A)]
[°C]
[W]
39/47
50/35
70
55
26
120
55
39
120
39/47
45/31
70
55
39
120
EN: Motor
FR: Moteur
DE: Motor
SE: Motor
NO: Motor
DK: Motor
FI: Moottori
NL: Motor
ES: Motor
IT: Motore
PL: Silnika
RU: двигатель
EN: Voltage
FR: Tension
DE: Spannung
SE: Spänning
NO: Spenning
DK: Spænding
FI: Jännite
NL: Voltage
ES: Tensión
IT: Tensione
PL: Napięcie
RU: Напряжение
) Peut être connecté 440V3~ ou 500V3~.
5
) Kann an 440V3~ und an 500V3 angeschlossen
5
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Voltage
Amperage
Weight
[V]
[A]
[kg]
400V3N~*
21,7
4
22
230V3~
37,5
400V3N~
29,5
25
400V3N~
43,9
28
440V3~*
13,4
5
24
500V3~
15,6
440V3~*
30,8
5
33
500V3~
35,1
EN: Amperage
FR: Intensité
DE: Strom
SE: Ström
NO: Strøm
DK: Strømstyrke
FI: Virta
NL: Stroomsterkte
ES: Intensidad
IT: Corrente
PL: Natężenie
RU: Сила тока
EN: Weight
FR: Poids
DE: Gewicht
SE: Vikt
NO: Vekt
DK: Vægt
FI: Paino
NL: Gewicht
ES: Peso
IT:0 Peso
PL: Masa
RU: Вес
7

Publicidad

loading