ENGLISH
INSTALLATION
1. TURNING OFF THE ELECTRICITY
Verify the wall switch is in the OFF position.
•
Turn off power at the circuit breaker that supplies power to the outlet box you are working on.
•
For screw-in type fuses unscrew the fuse that supplies power to the outlet box you are working on.
•
2. ATTACHING THE PHOTOCELL ON THE FIXTURE
Place the photocell (B) onto the receptacle on top of the fixture A
•
Twist the photocell (B) in the direction of the arrow indicated on the photocell until it locks into place.
•
CAUTION: Do not try to rotate the photocell receptacle on top of
the fixture as it may twist the wiring.
NOTE: The fixture comes with the twist-lock photocell (B) provided
separately in the box.
NOTE: The light fixture will not work without the photocell inserted into
the photocell receptacle as it completes the circuit.
NOTE: Make sure the photocell is locked on the receptor. Do not over
rotate after it is locked.
3. PREPARING TO MOUNT THE FIXTURE
NOTE: The fixture comes with the wire guard protection plate (C) already
installed on the fixture arm (D)
WALL MOUNT
Remove the wire guard protection plate (C) from the arm (D) of the fixture by loosening
•
the screws.
Mark and pre-drill the three holes on the desired location of the mounting surface.
•
EXTENSION ARM MOUNT (SOLD SEPARATELY)
Remove the wire guard protection plate (C) from the arm (D) of the fixture by
•
loosening the screws.
Refer to below table for help in using the correct hardware based on your mounting surface material.
•
MOUNTING SURFACE
Brick
Wood pole
Masonry block
Metal wall panels
4. MOUNTING THE FIXTURE
Feed supply wires through the arm (D)
•
WALL MOUNT
Using the fixture (A) as a template, mark and pre-drill the three mounting holes.
•
Partially screw the bottom hex bolts (AA) and place the fixture's two bottom
•
mounting groves onto the bottom bolts (AA)
Then insert the top bolt (AA) and tighten all bolts to firmly secure
•
the fixture to the surface
NOTE: Use other suitable bolts or fasteners as applicable to your mounting surface.
LED Dust-to-Dawn Area Light Instructions
WARNING: Risk of electric shock. Disconnect power
at fuse or circuit breaker before installing or servicing.
HARDWARE
1/4 in. Hex head sleeve anchor (not supplied)
1/4 in. Lag bolts (supplied)
1/4 in. Toggle bolts (not supplied)
1/4 in. bolts, nuts, washers and flat backing plate (not supplied)
www.cooperlighting.com
2
B
A
3
4A
A
IL51870322
1
D
C
D
AA
AA
3