Descargar Imprimir esta página

Halo ALP90LSFSUNVDGY Manual De Instrucciones página 4

Iluminación led del anochecer al amanecer

Publicidad

Idiomas disponibles

Idiomas disponibles

IL51870322
EXTENSION ARM MOUNT
Secure the extension arm (not included) to the light fixture arm (D) using
the included arm mounting bracket (DD) and the screws removed earlier,
until the bracket pushes firmly against the arm mount.
IMPORTANT: The extension arm is sold separately. If you need to purchase
the extension arm please contact your retail store. Installation instructions for the
extension arm are available in the instructions sheet provided in the extension arm
package.
5. MAKING THE ELECTRICAL CONNECTIONS
WALL MOUNT
Thread the wires through the hole in the wire cover plate (C).
WALL AND EXTENSION ARM MOUNT
If necessary, strip 3/8 in. of insulation from the junction box or fixture (A) wires.
ON/OFF Wiring (Non Dimming) Method
Connect the fixture black wire to the supply black wire [(+) line] and fixture white
wire to the supply white wire [(-)common] by twisting the exposed wires together
and using the wire nuts (BB). Ensure there are no loose wires
Connect the supply ground wire to the green fixture ground wire by twisting the
exposed wires together and using the wire nuts (BB).
0-10V Dimmable Wiring Method
Connect the fixture black wire to the supply black wire [(+) line] and fixture white wire to the supply white wire [(-)common] by twisting the
exposed wires together and using the wire nuts (BB). Ensure there are no loose wires.
Connect the supply ground wire to the green fixture ground wire by twisting the exposed wires together and using the wire nuts (BB).
Connect the purple wire to the (V+) DIM wire and the pink wire with (V-) DIM wire by twisting the exposed wire together and using the wire
nuts (CC).
NOTE: Hold stripped ends near each other and align any frayed strands (do not twist wires). Push the wires into the frayed strands (do not twist wires).
Push the wires into the wire nut (BB) and use your fingers to twist the wire nut clockwise until tight. Check for tightness by pulling wires.
Non-Dimming Wiring Diagram
(+) Line
(-) Common
Ground
6. SECURING THE FIXTURE AND WIRING
WALL MOUNT
Once the fixture is wired, place the wire cover plate (C) on the arm (D) by tightening the two screws removed earlier.
EXTENSION ARM MOUNT
After wiring is complete, secure the fixture on the extension arm using the arm mounting bracket (DD) by tightening the screws removed
earlier, until the arm mounting bracket(DD) pushes firmly against the pole.
6A
4
3/8 in.
Black
Lighting
White
Fixture
Green
6B
D
C
4B
5
0−10V Dimming Wiring Diagram
(+) Line
(-) Common
(+)DIM V+
(-)DIM V-
Ground
DD
LED Dust-to-Dawn Area Light Instructions
ENGLISH
D
DD
A
C
Black
White
Purple
Lighting
Fixture
Pink
Green
www.cooperlighting.com

Publicidad