must be removed from the device.
Observe the maximum pressure of the infl ated products. Use a pressure gauge (built-in or separate) to control the pressure inside
the infl ated product. Exceeding the maximum pressure may cause damage to the infl ated product or even its rupture. Rupturing
the product can cause serious injuries.
Periodically check that the readings of the pressure gauge built into the tool match those of the calibrated pressure gauge.
Check the tool for damage before each use. If you notice any cracks, abrasions or other damage, do not use the tool until the
defects are removed.
The device is designed for use with fl exible pressure hoses only. The hoses connected to the device should withstand at least the
pressure that the compressor is capable of producing. Hoses for pressures higher than 7 bar / 0.7 MPa should have a protective
cord, e.g. in the form of wire ropes.
Before connecting the hose to the device, check that the hose is not damaged. If abrasions, cracks or air leaks of the insulation
are discovered, stop using the damaged hose and replace it with a new hose before commencing work.
Never bend or twist the hose during operation. Bending the hose can reduce its internal diameter even to the point where the air
fl ow stops. This can lead to damage to the hose or even to its rupture, which can result in serious injuries. Bending and twisting
the hose also speeds up hose wear. Never carry the tool holding it by the hose. Do not overtension the hose during operation.
Avoid creating long lines for transferring compressed air. Shorter lines are easier to control.
All devices and accessories connected to the compressor should withstand at least the pressure that the compressor is capable
of producing.
It is forbidden to adjust or modify the safety valve on your own. The improperly adjusted or modifi ed safety valve may cause
damage to the product, which may result in serious injury.
Do not use the device as an artifi cial respiration device, for spraying any substance or any other application not described in the
instructions manual.
Never point the air stream towards yourself, other people or animals. Do not use your fi nger or any other part of the body to check
if the device is pumping air.
Make sure that the device is turned off before connecting the hose and accessories to the device.
The device is not intended to be used by children.
PRODUCT OPERATION
Preparing for operation
Unpack the product by removing all packaging components.
Check that the product power switch is in the off position – O.
Check that the drain valve is closed. The lever parallel to the valve means open valve, whereas the lever perpendicular to the
valve means closed valve.
Reduce pressure with a pressure regulator. The regulator knob allows for rotation only after it has been unlocked. The regulator
is unlocked by pulling the knob. Turn the knob as far as it will go in the direction indicated by the arrow marked with a minus sign.
Then lock the knob by pressing it. Locking the knob protects against an unintentional change of its position and thus unintentional
pressure adjustment.
Connect a fl exible hose to the air outlet. The outlet is equipped with quick-release coupling. When connecting, simply push the
hose plug into the air outlet socket until the latch mechanism is engaged. A correctly attached hose cannot be disconnected oth-
erwise than by pulling the sleeve around the air outlet in the opposite direction to the air outlet.
Mount the selected accessory to the other end of the hose, e.g. the infl ating gun.
Connect both batteries to the device. Slide each battery into the battery socket guides so that the battery latch holds it in place
in the compartment.
The tool is powered by two batteries. It will not start if one of the batteries is not installed in the tool or is fl at. The batteries in the
tool are connected in series, which means that the tool is supplied with the sum of their rated voltages. It is recommended that
both batteries have the same capacity and are charged to the same level. The batteries used to supply the tool should also have
the same level of wear. It is not recommended connecting a fl at battery with a new one, even if both batteries are charged to the
same level and have the same capacity. Failure to comply with the above recommendations will result in shorter operating times
and faster wear of the batteries used to supply the tool.
The product is ready for use.
Turning on and off
The power switch is used to turn on the device. Move the power switch to the on position – I, the product will turn on. Moving the
power switch to the off position – O stops the product operation.
If the product is turned on, it will automatically turn on and off the compressor that will fi ll the tank. Tank fi lling will start when the
pressure in the tank drops below 6 bar and fi nish when the pressure in the tank reaches 8 bar. This process will continue until
the device is turned off or the supplying batteries run fl at. The tank pressure gauge marked TANK allows for checking the current
pressure in the tank.