Failure
Possible phenomena
SPA The buzzer
Buzzer does not stop
of the pump
sounded
continuously
SPA Water tank
SPA Pool damage
leaks
Water is not
Insufficient filtering time
clean
Filter cartridge is dirty
The water is not clean.
Improper handling of
water.
18
Solution
Cleaning/Replacing filter
cartridge
Check if the water inlet and
outlet are block by foreign
bodies such as scale
Press and hold the filter
key 3 seconds to eliminate
sound
Use the provided repair
patch
Increase filtration time
Cleaning/Replacing of filter
cartridge
Replace the water
Refer to the chemical
instruction operation
6.2 Trouble codes and FAQ instructions
Trouble
E1
codes
Description
The malfunction of
temperature control sensor
Faults
The digital tube displays the
phenomena
trouble code "E1". The
heating function cannot be
used while the filtering and
wave-making can still work
Fault cause Short circuit or open circuit
of temperature sensor
Fault check
Please contact customer
and
service for professional
maintenance
maintenance
E2
High temperature protection
indication
The digital tube displays the
trouble code "E2". All
functions will not work.
When the water temperature
from the pool to the pump
exceeds 47℃, the electronic
control system automatically
provides electronic protection
to prevent people from
scalding
Step 1: Turn off the power
Step 2: Steps to solve
1) Confirm that the pool
water temperature is
between 20℃ and 40℃, and
the normal display and
function can only be restored
after the restarting and the
temperature is normal.
2) Remove foreign bodies
from the inlet and outlet of
the pool.
Step 3: Power on again to
use (if the alarm cannot be
cleared, please contact
customer service)
19