Programming The Functioning - Aprimatic BUONGIORNO Instrucciones Para La Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

R

4.3.5 Programming the functioning

Jumper
Jp1 : destined for the functioning with one or two wings.
ON = connected OFF = disconnected
ON = double wing
OFF = single wing
Jp2 & Jp3: destined for the delayed closing of the wing
standing above. ON = connected OFF = disconnected
!
Warning
Turn off the machine for at least 20 seconds before changing the jumper position.
Information
In the case of single-wing function, the electronic card ignores any pre-set wing closing delay and, by pressing
the CLOSE control, the response is immediate.
(ø2 x 1,5)
+
230 V
50 Hz c.a.
-
L
C1
N
Wing closing
last
(ø2 x 1,5)*
(ø2 x 0,75)
M2
F1
L
C1
N
LD1
J1
1
C2
1 2 3 4 5 6 7 8 9
EB
- 41 -
Jp2
Jp3
ON
ON
OFF
ON
ON
OFF
OFF
OFF
(ø2 x 1)*
(ø2 x 0,5)
EB
RL1
RL2
J2
J3
C2
2
3
4
5
6
7
8
9
-
-
M1
M2
DELAYED CLOSING
OR
SINGLE-WING
4
I n s t a l l a t i o n
Closing delay
1 second
3 seconds
6 seconds
12 seconds
Wing closing
first
M1
(ø2 x 1,5)*
(ø2 x 0,75)
(ø8 x 0,25)
Interface
module
FE
(ø3 x 0,5)*
(ø3 x 0,25)
* For lengths over 5 m.

Publicidad

Tabla de contenido
loading

Tabla de contenido