About Your System:
Specifications:
Flow Rate GPM US (LPM) Max*
Unit Dimensions (L x W x H)
Power Input
Operating Pressure Range
Feed Water Temperature Range
Unit Volume
Ambient Temperature Range
Inlet Port Size
Outlet Port Size
Minimum distance for adjacent combustible materials
Conditions for Operation:
Water quality will impact the performance of your UV system, and the following levels should be utilized as a guideline for pre-
treatment requirements of the influent water supply prior to UV treatment:
Iron................................................. < 0.3 ppm (0.3 mg/L)
Turbidity ......................................... < than 1 NTU
Tannins .......................................... < 0.1 ppm (0.1 mg/L)
Manganese..................................... < 0.05 ppm (0.05mg/L)
Hardness ........................................ < 120 ppm (7 grains per gallon)
UV Transmittance ........................... > 75%
If you are using untreated surface water or untreated groundwater as your source of supply, the suitability of the water supply for
potable applications must be confirmed by the provincial/state and/or local health agency that has jurisdiction.
If the test results indicate that: (1) any of the above contaminant levels are being exceeded, or (2) any prevailing drinking water
health standards are not being met, additional pre-treatment options must be installed that will eliminate all contaminants
posing health risks. Non-municipal water should be tested on an ongoing basis to ensure treatment efficiency.
3
15 (56)
68.6cm/27" x 21.6cm/8.5" x 79.4cm/31.25"
115V / 60Hz
30 - 100 PSI
40 – 99 ˚F (4 – 37 ˚C)
17L / 4.5G
36 – 104 ˚F (2 – 40 ˚C)
3/4" - 1" NPT
3/4" - 1" combo NPT
15 cm/6"