5.3 Parameter settings
There are two levels of protection for parameters:
a) User (U): with immediate access, User-changeable;
b) Password protected Factory/Service (F/S): password required for access; Factory-set parame-
ters.
5.3.1 Condensate drain
There are two operating modes:
a) TIMED (TIm) - with draining at intervals and settable time;
in this confi guration keep pressed
to work.
b) The symobl of the "condensate drain ON" will appear.
EXTERN (CON) - if there is an external drain. For chosing
the set proceed as follows: Press button
seconds to enter on menu User-changeable.
Using buttons
and
select "CHd" and press
to confi rm.
Using buttons
and
select "TIm" or "CON" .
esc
Press
to confi rm and exit.
In the same way it is possible to change interval and
discharge times of the drain.
Parameter table
Code
Defi nition
dON
Time ON Drain (sec.)
dOFF
Time OFF Drain( 1=10 sec.)
CHd
Confi guration drain
relay alarm/warning
OFF = relay energised for alarms/warnings
ALC
ON = relay energised only alarms
ST1 = relay energised for No alarms/warnings present
ST2 = relay energised for No alarms present
English
to force the drain
Flow Chart
set
>5 sec.
set
over 5
set
Menu
User
esc
CON
Default
Min
5
12
TIm
TIm
ON
SPS0010-SPS0250 (60Hz)
5.3.2 Alarms/Warnings
When an alarm is ON, the "alarm/war-
ning code" fl ashing on display.
Multiple alarms appear in sequence.
The symbol appears
In any case you can press
the alarms, and using the buttons
and
you can see all the
alarm code present.
esc
Press
to exit.
Code
Description alarm / warning
---
No alarms/warning present
CHd
HdP
Alarm High Dew point
LdP
Alarm Low Dew Point
set
DSE
Alarm sensor B1 faulti/disconnected
H
Warning High Dew point
TIm
L
Warning Low Dew point
SSE
Alarm sensor B2 faulti/disconnected
Max.
1
60
2
270
CON
-
-
Flow Chart
set
<5 sec.
Code 1
Code 2
.
Alarm
Alarm
set
Warning
Warning
to see
esc
esc
Code....
Alarm
Warning
esc
5/8