10 USER INTERFACE
Power
Click adjustment knob, the display will turn on
Click the adjustment knob again, the display will turn off
C/F Conversion
Press the adjustment knob for 3 seconds, the display will change from Fahrenheit to Celsius or vice
versa
Temperature Control
Turning the knob clockwise increases the set output water temperature
Turning the knob counter clockwise decreases the set output water temperature
You can set or adjust the temperature at any time between 80°F – 140°F (27°C – 60°C). The temperature
can be changed to your desired setting. The display will only stay on when the unit is in use or when you
are setting the temperature.
DANGER
Hotter water increases the potential for Hot Water SCALDS
CAUTION – removing the cover to change the temperature set point exposes electrical shock and burn hazards,
which can cause INJURY or DEATH. Adjustment should only be done by a licensed plumber or electrician.
Heater input: 8kW –11kW –13kW
1. Hot Water Outlet
2. Cold Water Inlet
3. Celsius/Fahrenheit Conversion (Press & Hold 3 sec.)
4. Temperature Set Point Display
Input
8/11/13kW
18kW
24/27kW
36kW
Heater input: 18kW –24kW –27kW –36kW
5. Adjustment Knob & Temperature Control
6. Wire Connection
7. Brass Compression Nut
8. Brass Compression Ferrule
Height in(mm)
Width in(mm)
12 (292.1)
9.75 (247.7)
18 (431.8)
14 (355.6)
18 (431.8)
17 (431.8)
18 (431.8)
19 (482.6)
9. Electrical Strain Relief
10. Mounting Bracket (1")
Depth in(mm)
3.75 (95.3)
3.75 (95.3)
3.75 (95.3)
3.75 (95.3)
10