Descargar Imprimir esta página

Kenmore ELITE 625.382080 Manual Del Propietário página 23

Ocultar thumbs Ver también para ELITE 625.382080:

Publicidad

Idiomas disponibles

Idiomas disponibles

Rated service
flow rate
......................................................
6.0 gpm
Pressure
drop at rated service
flow rate ..........................................
10 psig
Pressure
drop at 9.6 gpm
....................................................
15 psig*
Supply
water pressure
limits (minimum
/ maximum)
..................
30-125
psi (207-862
kPa)
Supply
water temperature
limits (minimum
/ maximum)
...................
40-120
°F (5-49 °C)
Drain flow rate
.............................................................
3.4 gpm
Rated capacity
at chlorine
concentration**
of:
0.50 ppm .....................
2,280,000
gal.*
0.75 ppm .....................
1,520,000
gal.*
1.0 ppm ......................
1,140,000
gal.*
1.5
ppm
......................
760,000
gal.*
2.0
ppm
......................
570,000
gal.
Sediment
removal
with:
25-30 micron particle
size
.......................
89.9%
or greater*
30-40 micron particle
size
.......................
96.4%
or greater*
40 micron
particle size or larger ...................
99.4%
or greater*
* From independent laboratory test data.
** Typical residential chlorine concentration is 0.5 to 1.0 ppm.
This system conforms to NSF/ANSI 42 for the specific performance claims as verified and substantiated
by test
data.
Installations In The Commonwealth
Of Massachusetts:
The Commonwealth
of Massachusetts
requires
installation be performed by a licensed plumber.
Plumbing code 248--CMR of the Commonwealth
of
Massachusetts must be followed in these cases.
TRANSFORMER
I
_
I
24VAC
BACK OF
ELECTRONIC
CONTROLLER
ii
120VAC
60Hz
TURBINE
I
SENSOR
m
24VDC
MOTOR
NC
?
NO
POSITION
SWITCH
Figure 24