6
Mounting/Installation
Pos : 80 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Sic herheit (--> Fü r alle Dokumente <--)/Warnhinweis e/Sic herheit - Ni eders pannungs- und 230 V-Leitungen @ 18 \mod_1302617821491_15.doc x @ 103465 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 100-240V.
Low-voltage and 100-240 V cables must not be installed together in
a flush-mounted socket!
In case of a short-circuit there is the danger of a 100-240V load on
the low-voltage line.
Pos : 81 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Sic herheit (--> Fü r alle Dokumente <--)/Warnhinweis e/Sic herheit - F ac hkenntniss e @ 18\mod_1302774384017_15.doc x @ 103564 @ 2 @ 1
6.1
Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering
knowledge and experience.
Incorrect installation endangers your life and that of the user of the
electrical system.
Incorrect installation can cause serious damage to property, e.g.
due to fire.
The minimum necessary expert knowledge and requirements for the
installation are as follows:
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1.
2.
3.
4.
5.
Use suitable personal protective clothing.
Use only suitable tools and measuring devices.
Check the type supply network (TN system, IT system, TT system)
to secure the following power supply conditions (classic connection
to ground, protective earthing, necessary additional measures,
etc.).
Pos : 82 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Montage/M ontagehinweise - Allgemein @ 19\mod_1310563670478_15.doc x @ 107743 @ 2 @ 1
|
Disconnect from power.
Secure against being re-connected.
Ensure there is no voltage.
Connect to earth.
Cover or barricade adjacent live parts.
— 8 —