RECIRCULATION VERSION AIR OUTLET
• Cut a hole ø 125 mm in any shelf that may be positioned over
the hood.
• Insert the reducer flange 9 on the hood body outlet.
• Connect the flange to the outlet on the shelf over the hood by
using a flexible or rigid pipe ø120 mm.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Fix the air outlet grid 8 on the recirculation air outlet by using
the 2 screws 12e (2,9 x 9,5) provided.
• Ensure that the activated charcoal filters have been inserted.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.
• Rest the shelf frame 10 (optional) over the bottom edge of the
hood body, aligning the fixing holes.
• Fix from below using the 4 screws 12n (3.5 x 16) provided..
EN
Fitting Shelf frame
12e
8
ø 125
12n
9
10
1
10
0