IO-Link Data Dictionary
21.10.01.00176/00
64
0x0040
2
Sensor Value LO
64
0x0040
3
Sensor Value HI
66
0x0042
1
Supply Voltage
66
0x0042
2
Supply Voltage LO
66
0x0042
3
Supply Voltage HI
Communication Mode
564
0x0234
0
Communication Mode
Counters
140
0x008C
0
Counter cc1
141
0x008D
0
Counter cc2
Counter ct1
143
0x008F
0
Counter ct2
144
0x0090
0
Diagnosis
Device Status
32
0x0020
0
Error Count
36
0x0024
0
IO-Link Device Status
Detailed Device Status
37
0x0025
1-15
130
0x0082
0
Active Error Code
138
0x008A
1
Extended Device Status - Type
138
0x008A
2
Extended Device Status - ID
Condition Monitoring [CM]
146
0x0092
0
Condition Monitoring
160
0x00A0
0
Actual Leakage Rate
Parameter ISDU 138 - Extended Device Status
Type
Type Color
ID
0x10
0x0000
Green
0x21
0x0002
Yellow
0x22
0x0007
Yellow
0x22
Yellow
0x000A
0x22
Yellow
0x0017
0x41
Orange
0x000C
0x41
Orange
0x000D
0x41
0x0015
Orange
0x42
0x0010
Orange
0x42
0x0011
Orange
0x42
0x0016
Orange
0x81
0x0000
Red
Implemented IO-Link Events
Event code
Event name
dec
hex
4096 0x1000
General malfunction
16384 0x4000
Overtemperature
20736 0x5100
General power supply fault
20752 0x5110
Primary supply voltage over-run
Short circuit
30480 0x7710
35872 0x8C20
Measurement range over-run
Calibration OK
6144 0x1800
Calibration failed
6145 0x1801
Teach-In completed successfully
6149 0x1805
Teach-In command failed
6150 0x1806
Leakage rate above limit
6153 0x1809
6156 0x180C
Primary supply voltage out of range
J. Schmalz GmbH
2 bytes
ro
2 bytes
ro
2 bytes
ro
2 bytes
ro
2 bytes
ro
1 byte
ro
4 bytes
ro
4 bytes
ro
4 bytes
ro
4 bytes
ro
2 bytes
ro
1 byte
ro
15 x 3 bytes
ro
1 byte
ro
1 byte
ro
2 bytes
ro
1 byte
ro
2 bytes
ro
Type Text
Status Text
Everything OK
Everything OK
Warning lower
Leakage rate above limit
Warning upper
Primary supply voltage US outside of operating range
Warning upper
Sensor calibration failed
Warning upper
Teach-In failed
Critical condition lower
Overload OUT1
Critical condition lower
Overload OUT2
Critical condition lower
Overtemperature
Critical condition upper
Primary supply voltage US too low
Critical condition upper
Primary supply voltage US too high
Critical condition upper
IO-Link communication interruption
Defect lower
Internal parameter data invalid
Event type
Remark
Error
E01 - Internal Error
Error
E19 - Overtemperature
Error
E07 - Primary voltage US too low
Warning
E17 - Primary voltage US too high
E11 - Short circuit at Out1
Error
E12 - Short circuit at Out2
Error
Overflow of sensor value, invalid measurement
Notification
Calibration offset 0 set successfully
Notification
E03 - Sensor calibration failed
Notification
New values taught for SPx, rPx or FHx, FLx, hyx
Notification
E20 - Teach-In failed
Warning
Condition Monitoring: leakage rate above limit
Warning
Condition Monitoring: primary supply voltage US outside operating range
2 of 2
VSi HD series
J. Schmalz GmbH
Johannes-Schmalz-Str. 1, D 72293 Glatten
Tel.: +49(0)7443/2403-0
www.schmalz.com
info@schmalz.de
Lowest measured sensor value since power-up
Highest measured sensor value since power-up
Supply voltage as measured by the device (unit: 0.1 Volt)
Lowest measured supply voltage since power-up
Highest measured supply voltage since power-up
0x00 = SIO mode
0x11 = IO-Link revision 1.1 (set by master)
Switch-on counter for switch point 1 (non-erasable)
Switch-on counter for switch point 2 (non-erasable)
Switch-on counter for switch point 1 (erasable)
Switch-on counter for switch point 2 (erasable)
Number of errors since last power-up
0 = Device is operating properly
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure
Information about currently pending events
Fixed-length array format according to IO-Link specification V1.1
0 = No error
1-99 = Error code displayed by the device
Type code of active device status (see below)
ID code of active device status (see below)
Bit 2: Leakage rate above limit -L- (not for VSi P10)
Bit 5: Supply voltage outside of operating range
Leakage rate, unit mbar/sec (not for VSi P10)
21.04.2022
VSi Data Dictionary