Manufacturer warrants, to the purchaser and subsequent owner
during the warranty period, every new product to be free from
defects in material and workmanship under normal use and service,
when properly used and maintained, for THE PERIOD MENTIONED
IN THE CHART BELOW FOR THE SPECIFIC MODEL PURCHASED,
from the date of purchase. Proof of purchase is required. Parts that
fail within the warranty period, that inspections determine to be
defective in material or workmanship, will be repaired, replaced or
remanufactured at Manufacturer's option, provided however, that by
so doing we will not be obligated to replace an entire assembly, the
entire mechanism or the complete unit. No allowance will be made
for shipping charges, damages, labor or other charges that may occur
due to product failure, repair or replacement. This warranty does not
apply to and there shall be no warranty for any material or product
that has been disassembled without prior approval of Manufacturer,
subjected to misuse, misapplication, neglect, alteration, accident or
act of nature; that has not been installed, operated or maintained in
accordance with Manufacturer's installation instructions; that has
been exposed to outside substances including but not limited to the
following: sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon
derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive
In instances where property damages are incurred as a result of an alleged product failure, the property
ELECTRICAL PRECAUTIONS- Before servicing a pump, always shut off the main power breaker and then unplug the pump
- making sure you are not standing in water and wearing insulated protective sole shoes. Under flooded conditions, contact your local
electric company or a qualified licensed electrician for disconnecting electrical service prior to pump removal.
Submersible pumps can become pressurized under normal operating conditions — allow 2-1/2 hours after disconnecting before
attempting service.
CONDITION
A. Pump will not start or run.
B. Motor overheats and trips
overload or blows fuse.
C. Pump starts and stops too often.
D. Pump will not shut off.
E. Pump operates but delivers little
or no water.
F.
Drop in head and/or capacity after
a period of use.
G. If tank or fittings leak.
If the above checklist does not uncover the problem, consult the factory. Do not attempt to attempt to service or disassemble pump. Service must be
performed by Zoeller Authorized Service and Warranty Centers. Go to www.zoellerpumps.com to find the authorized service center in your area.
Limited Warranty
Qwik Drain
Basin
105-0032
Part Number
2 year limited warranty
Warranty
owner must retain possession of the product for investigation purpose.
Service Checklist
COMMON CAUSES
Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal bound
mechanically, defective capacitor or relay when used, motor or wiring shorted. Float assembly held
down. Switch defective, damaged, or out of adjustment.
Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound mechanically,
defective capacitor or relay, motor shorted.
Float too tight on rod, check valve stuck, or none installed in long distance line, overload open, switch
defective.
Debris under float assembly, float or float rod bound by basin sides or other, switch defective, damaged or out of
adjustment.
Check strainer housing, discharge pipe, or if check valve is used, the vent hole must be clear. Discharge
head exceeds pump capacity. Low or incorrect voltage. Incorrect motor rotation. Capacitor defective.
Incoming water containing air or causing air to enter pumping chamber.
Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemicals could
possibly deteriorate impeller and pump housing. Check line. Remove base and inspect.
Carefully tighten pipe joints (use pipe dope) and screws. Check gasket location, tighten lid evenly. Do
not over tighten fittings or screws.
© Copyright 2024 Zoeller
substances, wash towels or feminine sanitary products, etc. in all
pumping applications. The warranty set out in the paragraph above
is in lieu of all other warranties expressed or implied; and we do not
authorize any representative or other person to assume for us any
other liability in connection with our products. Contact Manufacturer
at zcotechnical@zoeller.com or +1-800-928-7867 to obtain any needed
repair or replacement of part(s) or additional information pertaining
to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED
OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR
A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED
TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied
warranty, so the above limitation may not apply to you. Some states
do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have
other rights which vary from state to state.
Qwik Drain Pro
105-0031
3 year limited warranty
Co. All rights reserved.
®
2

Publicidad

loading

Este manual también es adecuado para:

Qwik drain pro 105-0031