The program is exited automatically 5 seconds after the selection of the desired cycle duration
5. Table of errors
Error code
EP 1
EP 2
E1 LO
temperature of probe T1 is too low (below 0°C) (or an open circuit in the probe)
E1 HI
temperature of probe T1 is too high (above 110°C) (or a short circuit in the probe)
E2 LO
temperature of probe T2 is too low (below 0°C) (or an open circuit in the probe)
E2 HI
temperature of probe T2 is too high (above 110°C) (or a short circuit in the probe)
E3 LO
temperature of probe T3 is too low (below 0°C) (or an open circuit in the probe)
E3 HI
temperature of probe T3 is too high (above 110°C) (or a short circuit in the probe)
E4
Et
E1
E2
safety temperature exceeded – error displayed after the completion of emergency rinsing
6. Start-up of the device
Turn on the switch located on the wall, open the dishwasher door, place the overflow plug in the
appropriate place (fig. 8) and close the door of the device. Press the
the tank and the boiler are filled with water, the boiler heating element will start operation. After the
heating of water in the boiler is completed, the dishwasher chamber water heating cycle will begin.
Insert the basket into the device chamber and wait until the water in the chamber reaches the set
temperature. Before starting the wash cycle, it is necessary to select the program. The wash cycle
is activated automatically by opening and closing the dishwasher door. If the door is opened during
the wash cycle, the program stops automatically. After the door is closed, the program continues the
wash cycle. The completion of the wash cycle program is indicated by a sound signal from the control
board. Remove the basket from the device chamber.
Water for washing
Water for rinsing/sanitizing
7. Emptying of the tank in models equipped with a drain pump
Turn the device off by pressing the
overflow plug and close the door. Turn the drain pump on using the
ining process proceeds automatically until the tank is completely emptied of water. In order to reac-
tivate the device, put the overflow plug back in its place, close the door and press the On/Off switch.
However, if the device will not be used any more, turn the main switch off.
8. Emptying of the tank in models not equipped with a drain pump
Turn the device off by pressing the
– the set time is 90 seconds
– the set time is 120 seconds;
– the set time is 180 seconds;
filling time exceeded, but a second attempt was undertaken
double filling time exceeded, attempts terminated
power outage during the operation of the dishwasher
temperature difference between probe T1 and T2 is too high (>30°C)
the switch , then open the door of the device, remove the
Error description
boiler overheating
60-65°C (140-149°F)
82-90°C (181-194°F)
switch , then open the door of the device, remove the
- 37 -
switch button . After
button. The dra-

Publicidad