SETTING THE FUNCTIONS
The various options described in table 3 can be selected using the function dip-switch (det.1, fig.1).
✓ Keep in mind that, in order to enable the control unit to learn a change in the settings, it is necessary
to momentarily cut off and then restore the power supply, or to press the RESET button.
TAB. 3
Function
n.
Off - On
OFF
OFF
STEP-BY
ON
-STEP
1
OFF
AND
PEDESTRIAN
2
INPUT MODE
OFF
ON
ON
ON
COMMAND
INPUT
OFF
MODES WITH
3
ACTIVE
SAFETY
ON
DEVICES
OFF
RE-
4
CLOSURE
TIMER
ON
OFF
WARNING
5
LIGHT
OUTPUTS
ON
(*) ATTENTION!
The use of radio control commands, even in the "Dead man" mode, requires the use of
safety systems which conform to the standards EN 13241-1 and EN 12453-1.
MOTOR TORQUE ADJUSTMENT
The T21X control unit allows you to vary the voltage delivered to the motor, thus limiting its power.
This function, which is very important for improving the safety of the automation, is controlled via trimmer T1
(det. 2, fig.1).
✓ The T1 control is overridden at the beginning of each manoeuvre, when the motor is fully powered
for a few seconds (starting power).
26
Mode
During opening, upon pressing the P/P button the gate
OPEN - STOP
stops, pressing it again the gate closes.
- CLOSE
During closing, upon pressing the P/P button the gate stops,
pressing it again the gate opens.
During opening, upon pressing the P/P button the gate stops
OPEN -
for a few seconds and then closes.
CLOSE
During closing, upon pressing the P/P button the gate stops
for a few seconds and then opens.
TD = TA
The P/P input becomes the opening button input.
The PED input becomes the closing button input.
TAP = TC
The P/P input becomes the opening button input.
TD = TA (UP)
The PED input becomes the closing button input.
TAP = TC (UP)
Both inputs are "Dead Man" commands
with active safety devices the control unit blocks all automatic
NORMAL
movement
with active safety devices the control unit will complete the
DEAD MAN*
movement in "Dead Man" mode
After one complete opening, the control unit only closes again
EXCLUDED
with a manual control.
After a complete opening cycle, the control unit will close after the
programmed pause time has elapsed. During the pause the
INSERTED
warning light will flash every 4 seconds, indicating the imminent
closure.
automatically and close in dead man mode.
both LP outputs are active during the movement of the
Fixed
motors using fixed voltage
both LP outputs are active during the movement of the motors
Intermittent
using intermittent voltage.
Descrption
With dip 3 set to ON the control unit will open