PROGRAMMING THE PEDESTRIAN OPENING FUNCTION
Control units T21 X allow you to program the pedestrian opening time.
In order to program the pedestrian time it is necessary to connect a pushbutton to the TAL input, or a receiver
model OC2 to the second programmed channel.
MANUAL procedure:
1 - Shut off power supply to control unit
2 - Position the gate at mid-travel.
3 - Press PRG button
4,5,6 - Switch on power to control unit by keeping the PRG button (part 3 of fig.1) pressed for at least 3 seconds.
Programming LED L1 comes on.
7 - Press pushbutton TAL (or transmit using the second channel): the rolling gate should move to close.
8 - When the gate has closed, press TAL once more (or transmit using the second channel).
9 - After a short pause, the gate will move to open.
10 - When the gate reaches the partial opening point desired, press TAL (or transmit using the second channel).
11 - After a short pause, the gate will move to close.
12 - When it has closed all the way, press TAL (or transmit using the second channel).
13 - Led L1 will go off, signalling the end of the programming procedure.
13 - Fin de la programación; el led L1 se apagará.
TAB. 6
TAL
FINAL TESTING
A final test should always be made after completing all programming procedures.
- Check correct operation of the protection devices (anti-crushing system, stop button, photocells, sensitive
edges etc.)
- Check correct operation of the signalling devices (flashing lights, gate open indicator etc.).
- Check correct operation of the control devices (TD push button, radio controls etc.).