ENGLISH
Installing the window sealing plate
You can install the window sealing plate either vertically (Fig. 8) or horizontally (Fig. 9). Adjust
the size of the opening so that the sealing plate remains fixed in it.
The following checks must be applied to installations using flammable refrigerants:
-
The charge size is in accordance with the size of the room within which the refrigerant
containing parts are installed.
-
Ventilation machinery and outlets are properly operated and unobstructed.
-
If an indirect cooling circuit is used, the secondary circuit must be checked for the presence
of refrigerant.
-
Equipment marking remains visible and legible. Markings and symbols that are illegible
should be corrected.
-
The components or refrigerant piping are installed in a location where they are not
susceptible to exposure to any substance that may corrode the refrigerant containing
components, unless the components are constructed of materials that are inherently
corrosion resistant or are adequately protected against corrosion.
4. OPERATION
The following functions can be activated from the control panel or from the remote control.
On/Off
When the device is turned on, it will beep and enter standby mode. Touch the power
key to turn the device on and off.
Cooling mode
Press the mode button once to select cooling mode.
Dehumidification mode
Press the mode icon to select dehumidification mode.
Fan mode
Press the mode button once to select fan mode.
Heating mode
Press the mode button once to select heating mode.
Note:
when the appliance is running in cooling and dehumidification mode, the condensate
drainage will be done through the upper condensate outlet. When the device is running in
heating mode, the condensate drainage will be done through the lower condensate outlet.
64
FORCECLIMA 9500 SOUNDLESS HEATING CONNECTED
Note:
when changing from heating mode and vice versa, the appliance will take some time
to change from one mode to the other. It may take a few minutes for the appliance to start
running normally again.
Sleep mode
In cooling mode, press the increase and decrease icons to activate the Sleep mode. The
device will operate saving energy and silently.
Time/temperature increase and decrease
Use these icons to increase or decrease temperature and time.
Temperature cannot be increased or decreased in fan or dehumidification
mode.
Fan-speed increase and decrease
Under the cooling mode, press the key to select high or low wind speed operation.
This option is not available under the dehumidification mode.
NOTE:
Under certain conditions (defrost), it may not operate at the selected speed.
Wi-Fi
Press and hold this button with the appliance in Standby mode until the button starts
flashing rapidly. Once this happens, see how to connect in section "5. Wi-Fi connection
and mobile App".
Timer
Press this key to set the timer. When the timer symbol blinks, use the increase and
decrease icons to select the desired operating time.
The timer can be set from 1 to 24 hours, and the digits increase and decrease by 1 hour.
Oscillation
Press this icon to toggle air oscillation.
Drainage instructions
When the air conditioner stops operating because the water tank is full, turn it off and unplug
it from the power supply. The full tank indicator (FULL) will start blinking and the appliance will
not operate until the water inside the tank is drained.
Manual drainage. Fig. 10
1.
Place a container below the water outlet behind the body.
Unscrew the drain cap and unplug the water plug. The water will automatically flow into
2.
a container.
ENGLISH
FORCECLIMA 9500 SOUNDLESS HEATING CONNECTED
65