Descargar Imprimir esta página

NODOR NorCook IH N3200 BK Manual De Instrucciones página 11

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

If the touch control is switched on, the cooking zone
can be selected by pressing the button (4) of the
corresponding zone.
The display (5) of the zone selected lights up, while the
remaining displays are dimmed. if the cooking zone is
"hot", "H" and "0" are alternately displayed.
Press the PLUS (3) or MINUS (2) button to select a setting
and the zone will begin to heat up.
Once the cooking zone has been selected, the setting
can be selected by keeping the PLUS (3) button pressed
down. The setting begins at level 1 and increases by 1
level every 0.4 seconds. When setting "9" is reached, the
setting will not be changed further.
If the setting level has been selected using the MINUS
(2) button, the start level is "9" (maximum level). Keep
the button pressed down to lower the active level by 1
every 0.4 seconds. When setting "0" is reached, there will
be no further setting changed. The setting can only be
changed by pressing the MINUS (2) or PLUS (3) button
again.
Switching a cooking zone off
Select the zone to be switched off using the corresponding
button (4). The display (5) of the zone selected lights up,
while the remaining displays are dimmed. Press the
Cooking zone (4) and MINUS (2) buttons at the same
time and the setting level of the zone is changed to 0.
Alternatively, the MINUS button (2) can be used to reduce
the setting level to 0.
If a cooking zone is "hot", "H" and "0" will be alternately
displayed.
Switching-OFF all cooking zones
Immediate switching-OFF of all cooking zones can be
achieved anytime by means of the ON/OFF key. In the
standby-mode an "H" appears on all cooking zones
which are "hot". All other cooking zone displays are not
illuminated.
Wattage settings
The output of the cooking zones can be set in 9 steps
which are indicated by the figures "1" thru "9" by means
of LED sevensegment-displays.
In case more power is required, select the boost level
("P")
Cooking Zones (EIM-3220 HT B)
There is a further option of two single cooking zones
operating together as if they were a single zone. This
function is enabled by simultaneously pressing the
selection keys "4" on both the zones to be combined.
The following symbol will then be shown on display "5"
of the rear area:
Display "5" located on the front area will indicate the
power level selected for the combined zone.
This function makes it possible to obtain a rectangular
cooking zone, particularly suited to rectangular or oval-
shaped pans.
If you are using a round pan, the minimum diameter of
the base should be 20 cm in order to ensure optimal
detection.
Boost function
After selection of a respective cooking zone, the boost
function can be activated by selecting the power level
9 and then pressing PLUS (3) button . By means of this
function certain cooking zones are enabled to receive
power over the nominal (the number of boostable
cooking zone depends on the power available on a
partial modules which is to be lees than total hob power
). If the desired cooking zone has the capacity to activate
the booster, the display shows a "P" symbol. In case the
available power is not enough the cooking stage display
flashes for 3 seconds on the cooking zone which needs
to be reduced and which requires automatic adjustment.
The boosting time is limited to 5 min to protect cooking
utensils. After the booster is switched off automatically,
the cooking zone continues operation on power level "9".
The booster can be reactivated after some minutes.
In case that the pan is removed from the cooking zone
during boosting, the boosting function remains active
and boosting time continues.
The power management is based on on the principle that
the last entry is requested by the induction as top priority.
That means that previous actions and settings also made
for the other cooking zones are reversed automatically,
if necessary.
- If induction identifies the necessity of reducing power
at a cooking zone, the selected cooking stage flashes
on that cooking zone providing a correction period of
3 sec before the power is reduced automatically to a
minimum cooking stage.
- If the setting is adjusted within the correction period,
the power management checks the settings again.
Should a new setting lead to further power reduction, the
correction period starts again.
- If no automatic correction needs being made to the
cooking zone setting, the flashing stops immediately
and the original value remains as a steady display
indication. Should the situation change again on the
power reduced cooking zone, no automatic power
increase is effected.
Residual heat indicator
It is meant to indicate to the user that the glass ceramic
has a dangerous touch temperature in the circumference
of a cooking zone. The temperature will be determined
following a mathematical model and the remaining
residual heat will be indicated by means of "H" on the
corresponding 7-segment display.
Heating-up and cooling down will be calculated
dependent on:
· the selected setting („0" to „9")
· the ON/OFF time.
After switching-OFF the cooking zone the respective
display shows "H" until the assigned cooking zone
temperature is mathematically in a uncritical level. (≤
60°C).
Automatic power OFF function (operating time
limitation) (Fig. 7)
Dependent on the selected setting, every cooking zone
will be switched-OFF after a defined maximum operation
time if no operation of the assigned cooking zone follows
within this time period. Every change of the cooking zone
condition (by means of the PLUS-, MINUS- key) puts
back the maximum operation time of this cooking zone
to the initial value of the operating time limitation.