INSTALLATION
On ferromagnetic surfaces it is not necessary to install
the magnetic base.
OPERATION
LPL 600 - LPL 900
The lamp will turn on automatically when it is powered.
LPL 600 SENSOR - LPL 900 SENSOR
At each power up LPL will flash for 15 seconds for sensor stabilization.
The lamp is equipped with a sensor that will turn on the LEDs when it detects movement.
It will automatically turn o a er 3 minutes from the last motion detected.
POWER CONNECTION
To connect and disconnect the cables, simply press the buttons in the figure.
SERIES CONNECTION
In both versions it is possible to connect multiple lamps in series using cables with a maximum section of
1.5mm or using the bridge supplied via the connectors in the figure.
To connect and disconnect the cables, simply press the buttons in the figure.
Check in the table below how many LPL can be connected according to the version and voltage.
PUSH
Power
connection
SAFETY INSTRUCTIONS
INSTALLATION MUST BE CARRIED OUT BY SPECIALIZED PERSONNEL ONLY
Sirena SpA C.so Moncenisio, 5-10-12-14-16 10090 ROSTA (TO) | Italia
Tel. +39 011 95 68 555
Series connection
via cables
NUMBER OF LPL THAT CAN BE CONNECTED IN SERIES
12
24
LPL600
5
6
LPL900
3
5
Fax +39 011 95 67 928
On other surfaces, fix the magnetic base with 4 Ø5mm
screws (distances shown in the dimensional section).
NB: install the base as shown.
Allineare
Allineare
12
24
48
6
8
8
3
7
8
www.sirena.it
V
Series connection
via bridge
E-mail: info@sirena.it
10/2023 Ref. 10-060-2113-000
x