Performance Data Sheet
Hotpoint SmartWater Filtration System
HWF Cartridge
Health Claim Performance Certified by NSF/ANSI*
'I00% safety factors built in for unmetered usage)
Parameter
Standard No. 42: Aesthetic
Effects
Chlorine
F&O
Pardculam**
200,000
Parameter
USEPA
MCL
Turbidity-
OysL
Lead at pH 6.5
Lead at pH 8.5
Lindane
Atrazdne
2,4-D
Asbestos
Iinelnent
Challenge
1.9 ppm
Effluent
Average
Maximum
0.02 ppm
0.05 ppm
3,978
7,800
% Reduction
Average
Minimmn
98.90%
97.37%
98.00%
96.10%
USEPA
MCL
1 NTU***
99.95% Reduction
15 ppb
15 ppb
0.0002 ppm
0.003 ppm
0.100 ppm
99%
Standard
No. 53: Health
Effects
In fluent
Effluent
Average
0.07 NTU
26
1 ppb
1.8 ppb
0.00005 ppm
0.002 ppm
0.0264 ppm
0.32 MFI/ml
Maximmn
0.1 NTU
55
1 ppb
4.3 ppb
0.00005 ppm
0.003 ppm
0.080 ppm
1.2 MFI Jml
Challenge
24.3 NTU
105,750
160 ppb
150 ppb
0.00062 ppm
0.0084 ppm
0,272 ppm
69() MFI/ml
Average
99.71%
99.97%
99.37%
98.80%
91.93%
76.19%
90.29%
99.95%
* Testedusing a flow rate of 0.5 gpm; pressure of 120psig; pH of Z5-+0,5; t emp. of 20-+2.5 C
** Measurement #7partioles/ml
*** NTU = Nephelometrio Units
% Reduction
Minimmn
99.59%
99.95%
99.37%
97.13%
91.93%
64.28%
70.58%
99.82%
Operating Specifications
_ Capacity-: certified for up to 300 gallons ( 1135 1); up to six mtmths for models without a replacement
filter indicator
light;
up to one year for models with a replacement
filter indicator
light
_! Pressure
requirement:
40-120 psi (2.8-8.2 bar), non-shock
_VFemperature:
33-100 F (0.6-38 C)
_ Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance
Requirements
_ Flush new cartridge
at full flow for 3 minutes
to purge out trapped
air.
_ Replace cartridge
when flow becomes too slow.
Special Notices
_ Installation
inslructions;
parts and service availabilily; and standard
warranly are included with the product when shipped.
_ This drinking
water system must be maintained
according
to manufacturer's
insu'uctions,
including
replacement
of
filter cartridges.
_ Do not use with water that is microbiologically
unsafe or of unknown
qualily without adequate
disinfection
before or after
the system. Systems certified for cyst reduction
may be used on disinfected
water that may contain
filterable
cysts.
_gThe contaminants
or other substances removed
or reduced
by this water treatment
system are not necessarily in your water.
_ Check for compliance
with the state and local laws and regulations.
System Tesmd and Certified
by NSF Intcrnalional
against ANSI/NSF
Standard
42 & 53 tor the reduction
of:
Standard No. 42: Aesthetic
Effects
Chemical
Unit
Taste and Odor Reduction
Chlorine
Reduction,
Class l
Mechanical
Filtration
Unit
Particulate
Reduction,
Class I
Standard
No. 53: Health Effects
Chemical
Reduction
Unit
Lead and Atrazine
Reduction
IJndane and 2,4-D Reduction
Mechanical
Filtration
Unit
Turbidity
Reduction
Cyst and Asbestos
Reduction
Manufactured
for: General ElectFic Company, I xmisville, KY 40225
25