• Inspect the case before using thermometer. Do not use thermometer if it appears damaged.
Look for cracks or missing plastic.
• Please refer to the emissivity information for the actual temperature. Highly reflective objects
or transparent materials can cause the measured temperature value to be lower than the
actual temperature.
• When measuring high temperature surfaces, please be aware not to touch them.
• Do not use thermometer in an environment close to flammable or explosive materials.
• Using thermometer around steam, dust, or environments with large temperature fluctuations
may lead to inaccurate temperature measurement.
• To ensure measurement accuracy, please place thermometer in the measurement
environment for 30 minutes before using.
• Avoid keeping thermometer near high temperature environment for long periods.
D:S ratio
Measuring range
LCD size
LCD display
Accuracy
Temperature coefficient
Repeatability
Emissivity
Response time
Spectral response
Auto power off
Low battery indication
High/Low temperature LED alarm
High/Low temperature audible
alarm
Data hold
Unit conversion (°C/ºF)
MAX/MIN/AVG/DIF mode
Lock measurement
Laser
Operating temperature
Storage temperature
Operating humidity
Drop test
Battery type
TECHNICAL SPECIFICATIONS
<0°C: ±(1.5°C+0.1 °C/°C); ≥0°C: ±1.5°C or ±1.5% of
reading, whichever is greater
<32°F: ±(3.0°F+0.1 °F/°F); ≥32°F: ±3.0°F or ±1.5% of
reading, whichever is greater
±0.1 °C/ºC or ±0.1%/ºC, whichever is greater
(±0.1 °F/ºF or ±0.1 %/°F, whichever is greater)
0.7°C or 0.7%, whichever is greater (1.5°F or 0.7%,
0.1-1.0 (adjustable, can store 5 sets of preset values)
Single laser, wavelength 630nm-670nm; output power
<RH90% (non-condensing)
20:1
32ºC~700ºC
25.6°F~1292°F
35x35mm
Color EBTN
whichever is greater)
≤250ms (95% of reading)
8um-14um
15s
√
√
√
√
√
√
√
<1mW, class 2 laser
0ºC-50ºC (32°F~122°F)
-20°C-60°C (-4°F~140° F)
1m
9V battery (6F22)
13