  • MEXICANO, página 71
FILLING THE DETERGENT TANK
Warning
From the range of recommended products, choose
the one most suited to the washing job to be done
(fig. 5) and dilute it with water according to the in-
structions on the pack.
Fill the detergent tank with the diluted product (fig.
6).
Ask your dealer for the catalogue of the detergents
that can be used depending on the type of washing
job to be done and the type of surface to be treated.
After using a detergent, the detergent intake circuit
must be flushed out with clean water.
FIG. 5
FILLING THE WATER SOFTENER TANK.
Fill the tank with water softener solution.
Use only products recom-mended by the manufactu-
rer and/or dealer. Follow the instructions given on
the packaging meticulously (Do not disperse water
softener in the environment) (fig. 7).
TRANSPORTING
To move the machine, disconnect it from the mains
electricity and water supplies, release the parking bra-
ke on the side of the machine and push it by the handle.
LIFTING WITH A FORKLIFT TRUCK
To lift the cleaner with a forklift truck insert the forks
in the slots provided. (fig. 8).
FIG. 6
26
FIG. 7
FIG. 8
COMMAND AND CONTROL DEVICES
Warning
Before connecting the machine to the water supply
and to the power mains, it is essential to know the
function of the cleaner's command and control de-
vices.
SAFETY DEVICES
The safety devices protect the user and the applian-
ce. They must not be tampered with or used for other
than their designated purpose.
Safety thermostat: This protects the high pressure
water circuit in the event of blockages or overhea-
ting. It can be reset manually or automatically.
Safety device on lance handgrip: Prevents the
trigger on the handgrip from being operated acci-
dentally.
Thermal cutout: stops the high pressure washer if
the electric motor overheats.
WATER CIRCUIT CONNECTION
Connect the feed hose to the mains (fig. 9A) and to
the hosetail on the cleaner (fig. 9B).
Check that the pressure and quantity of the water
supplied by the mains are sufficient for the cleaner to
work properly: 0,2 ÷ 0,4 MPa. (2 ÷4 bar) (29÷58 PSI).
Maximum temperature of feeding water 50°C
(122°F).