2.Pool Size Setting
a)
Initial Setting
First time turning on the power, after the device finishes self-checking, the display
panel shows "PXX.X" and flashes, then set the pool size. Press "+" / "-" key to adjust
the pool size, scale value with 0.1 m³, and the unit of the value is in cubic meters.
Press the "MENU" key to save the setting.
If the pool size is not set after the device finishes self-checking the system will
automatically use the default value to set the pool size. The default value depends
on the salt cell type.
Default value of pool size:
Dream Salt 25 (EL05) -- 10 m³
Dream Salt 50 (EL10) -- 20 m³
b)
Normal Setting
Press the shortcut key
the value of pool size. If there is no need to set the pool size, press the shortcut
key
.again to exit; or press the "MENU" key to set the pool size, the display panel
shows "PXX.X" and flashes, then set the pool size. Press "+" / "-" key to adjust the
pool size, scale value with 0.1 m³, and the unit of the value is in cubic meters. Press
the "MENU" key to save the setting and exit.
Note: The pool size has a setting range, which depends on the type of salt cell. The value
will not be changed when pressing "+" / "-" key if the value out of range.
Setting range of pool size:
Dream Salt 25 (EL05) -- 5 to 25 m³
Dream Salt 50 (EL10) -- 5 to 50 m³
3. Water Flow Detection
The display panel shows "-FL-" and flashes when the system detects water flow. After
continuous detection of water flow for 1 min, the system starts working. If the system cannot
detect the signal of water flow, the display panel remains showing "-FL-" until there is a signal
of water flow.
When the system is in the status of water flow detection, all the keys on the panel are locked
except the "POWER" key.
, the pool size indicator is on and the display panel shows
EN
6 | Page