Descargar Imprimir esta página

GRE Dream Salt GSS25 Manual De Instalacion Y Uso página 8

Clorador salino para piscinas elevadas

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
EN
User Interface
1. Function of the Indicator
 GENERATE: Work indicator. Model in normal operation, the LED light is steady on.
The light will be switched off once the model stops working
 ERROR: Error indicator. When the light is on, an error code will be shown on the
display panel. (EE01—Low water temperature; EE02—High water temperature;
EE03—High salinity)
 POOL SIZE: Pool size indicator. The light switches on when setting the pool size
 ADD SALT: Salt indicator. The light switches on when the salinity is low
 TIMER: Timer indicator. The light switches on when setting the timer function
 LO SALT: Low salt indicator. The light switches on when the salinity is low
 HI SALT: High salt indicator. The light switches on when the salinity is high
 SALINITY: Salinity indicator. The light switches on when checking the salinity
 BOOST: Boost mode indicator. The light switches on when setting boost mode
 ON/OFF: Power indicator. The light switches on when the power is turned on
4 | Page

Publicidad

loading

Este manual también es adecuado para:

Dream salt gss50Swim & fun 1428Swim & fun 1429