DERNIERE VERSION DES NORMES ET APPAREILS CALOREX
PEUT ETRE INSTALLE A
1,25M MAIS NE DOIT ETRE
PLACE A 2,5M AU-DESSUS
DE LA SURFACE DE LA
PISCINE
1) NB. LE DETECTEUR DE COURANT DIFFERENTIEL RESIDUEL (30mA) EST UN DETECTEUR
DE PERTE A LA TERRE ET NEST PAS TOUJOURS NECESSAIRE. NOUS RECOMMANDONS
NEANMOINS DE L'UTILISER SUR TOUTES LES INSTALLATIONS.
2) LE FUSIBLE DU DESHUMIDIFICATEUR DOIT ETRE CONFORME A LA NORME IPX APPROPRIEE.
BIEN QUE L'UNITE SE TROUVE
2,5M AU-DESSUS DE LA
HAUTEUR DE LA PISCINE, ELLE
N'EST PAS ACCESSIBLE POUR
LA MAINTENANCE ET N'EST
DONC PAS CONFORME AUX
NOUVELLES NORMES.
1,25 - 2,0 M. DOIT ETRE INSTALLE AVEC
UN DETECTEUR DE COURANT
DIFFERENTIEL RESIDUEL (30mA) ET DOIT
SE TROUVER AU MINIMUM A 300MM DU SOL
Page 3
DOIT ETRE INSTALLE AVEC
2,0-3,5M
DETECTEUR DE COURANT
DIFFERENTIEL RESIDUEL
TOUTE HAUTEUR
ACCEPTABLE
SI L'UNITE NE DEPASSE PAS
HORIZONTALEMENT 1,25M DE LA
PISCINE, ELLE DOIT SE SITUER A
2,5M AU-DESSUS DE LA SURFACE
DE LA PISCINE.
SD496250 iss 9