6. EXPLOSED VIEW
ES - 6. DESPIECE
PT - 6. VISTA DETALHADA
A
B
C
1
D
E
F
L
M
N
O
P
Q
5
Exterior elements
1. Type 2 Socket
2. Label
3. LED's
4. Door lock
ES - Elementos exteriores
1. Socket
2. Etiqueta
3. Iluminación LED
4. Cerraduras
Interior elements
A. Display
B. RFID
C. Antenna LTE
D. 12V power supply
E. MID Meters
F. 16A MCB and combined circuit breaker
G. 80A general protections 230V or 400V
H. Control boards
2
I. Contactors
G
J. 40A RCCB and combined circuit breaker 230V or 400V
3
K. Terminal block
4
ES - Elementos interiores
A. Display
H
B. RFID
C. Antena LTE
I
J
D. Fuente de alimentación 12V
E. Medidores
K
F. Automático/diferencial
combinado 16A
L
G. 230V o 400V General 80 A
H. Placa de Control
I. Contactores
J. 230V o 400V Automático/
diferencial combinado 40A
K. Borna de toma tierra
Control board elements
L. 12V power supply connection
M. Contactor control
N. SIM card
O. RS485 Modbus input and output terminals
P. RS485 Modbus
Q. HDMI
R. Compute module
S. USB
T. Ethernet
ES - Elementos Placa de Control
L. Conexión fuente de
alimentación 12V
M. Control de contactores
N. Tarjeta SIM
R
O. Bornas de entrada y salida
Modbus RS485
P. Modbus RS485
Q. HDMI
R. Compute module
S
S. USB
T. Ethernet
T
PT - Elementos exteriores
1. Tomada
2. Etiqueta
3. Iluminação LED
4. Fechaduras
PT - Elementos interiores
A. Display
B. RFID
C. Antena LTE
D. Fonte de alimentação 12V
E. Medidores MID
F. Disjunto diferencial combinado
16A
G. 230V o 400V Proteção Geral 80 A
H. Electrónica de Controlo
I. Contactores
J. 230V o 400V Disjunto diferencial
combinado 40A
K. Terminal de terra
PT - Elementos da Placa de Controlo
L. Conexão fonte da alimentação 12V
M. Controlo de contactores
N. Cartão SIM
O. Bornes de entrada e saída Modbus
RS485
P. RS485 Modbus
Q. HDMI
R. Compute module
S. USB
T. Ethernet